Indoor Air Quality Field Report, 90 Trinity Place, Mar 2002

Machine-extracted title · confidence 95%

ATC Associates indoor air quality field report for 90 Trinity Place detailing temperature, humidity, and pollutant levels in March 2002.

NYC-WTC_000180169–000180182
Page image
Scanned page image, NYC-WTC_000180181
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document SUBJECT TO PROTECTIVE ORDER NO. SEPI. 2008 CONFIDENTIAL, ATC ASSOCIATES, INC. INDOOR AIR QUALITY FIELD REPORT Time: 330 PŁOCATION: 76-Trinity Place/HS for Ieadership And Pablie Services Occupants NTeniperature (*F) Relative Humidity (%) Room# 315 Hallway OuT SIDE Poonybo? Hall way Elee Area 6Fl STAIRWEL'A' SFL Fl Hall Wey Stor Aree I' FlOOR Hall way By Room # 55 STAIECASE 'A'stApbOR STARCASE'A 4t FlOOR Hell way By RoM # 415 RoOm# 404 Guideline levels ASHRAE/AIHA / O 70.6 706 102 70 7 104 705 70-6 104 705 71.0 69-76°F/winter 73-78.5°F/summer 355 343 341 347 341 34-2 347 350 35-0 344 30-60% Carbon Dioxide (Ppm) 539 579 532 562 508 462 513 547 492 460 Outdoor level +700 ppm PagelBof iy DATE: 03/08/02 PROJECT NO:15-19125-0290 Carbon Paesn Respirable Monoxide Particulate (ppm) TYOCS (ppm) s (ug/m') 2 50 2 33 37 39 43 Comments: The assessed location(s) ( ) Does ( ) Dogg not mect established indoor air quality guidelines Signature: Prasad Doddapaneni/ Irase Deadoleu Date: 03/08/02 2 2 2 2 2 2 2 9 ppm 40 41 44 44 50 ug/m 1 ppm CITY_21MC100_003463602 NYC-WTC_000180181

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000180181Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000180206

ATC Associates indoor air quality field report for 90 Trinity Place documenting environmental conditions in May 2002.

Similar indexed content

NYC-WTC_000180049

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

Similar indexed content

NYC-WTC_000180033

Field report form documenting indoor air quality measurements taken at a school in May 2002.

Similar indexed content

NYC-WTC_000180023

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

Similar indexed content

Compare copies and versions →