NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1784
Lab Group #: 7376 Filter Type / Filter Area: MCE 385 mm’
Lab Sample #: 15 Grid Opening Size: 0.01124
Client Sample #: 17 Area Examined: 0.04496 mm’
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 4/10/02
Analysis Performed By:
MARK PEYSAKHOV
GO, Structure Structure Type Length ID of Structure N or V EOS
(Nonadb
No F B C M >-05 p >=5p Chrys Amphibole Nonasb Ambig/ND
No Coord Elements)
<5p
Struct = > 0.5u >5:1 Aspect Ratio Grid acceptance:
'J- Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded oroverfapped grid squares <5% F B C M =■5^
EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
E = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
Tremolite
M - Matrix Non-Identified
Actinolite
NSD = No Structures Detected
CONFIDENTIAL, CITY_21MC100_009505374
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000178877
OCR can misread numbers and units. Confirm readings against the page image before using them.