NYC 9/11 Public Portal Document
PSC Hnalytical Services G109219G67 p. 1G
Mar 04 02 03:26p
INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING
•EPAWLAP 101262-0 • NT DOH/NELAC 10903 ■NJ DEP P,A020
• AIHA ACCREDITATION NO. 100439 ■ PA DEP 06-353 • CT DPH PH-023B
"NC DENR599
AN AJ^Y'J'ICAT, SERVICES Analytical Results
for
ATC Associates
WorkOrder: R02020843
Client Reference: 19125-0297
AnaJyte Concentration Limit of Test Date Analyzed
Detection Method /Analyst
(ug) I : (ppm) (ug)
Client ID: M5 ATC-022I-M89 Lab ID: -05A Date Sampled: 2/21/02 Matrix: Filter Air Vol.(L); NA
Aluminum <1.00 1 N7300 MCE 03/03/2002 Aje
Cadmium <0.200 0.2 N7300 MCE 03/03/2002 AJB
Chromium 0.519 0.2 N73D0 MCE 03/03/2002 AJB
Cobalt <0,100 0.1 N7300 MCE 03/03/2002 AJB
Copper <0.200 0.2 N7300 MCE 03/03/2002 AJB
Iron <2.00 2 N7300 MCE 03/03/2002 AJB
Lead 0.300 0.3 N7300 MCE 03/03/2002 AJB
Magnesium <1.30 1.3 N7300 MCE 03/03/2002 AJB
Manganese <0.300 0.3 N7300 MCE 03/03/2002 AJB
Molybdenum <1.00 1 N7300 MCE 03/03/2002 AJB
Nickel <0.200 0.2 N7300 MCE 03/03/2002 AJS
Zinc <0.500 0.5 N7300 MCE 03/03/2002 AJB
(a) Analysis indicates possible breakthrough: back section result is greater than 0% of the front section result.
General Notes;
<: Less than the indicated limit of detection (LOD)
—; Information not available or not applicable.
Back sections were checked and showed no significant breakthrough.
Page 3 of 3
CONFIDENTIAL, CITY_21MC1OO_OO347435O
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000177756