NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York lOOlC
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/05/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification ;iy Selected.-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS';
Method: A:1ERA Final Rule, F?.A Federal Register (40 CFR, Part 76 3), Vol. 52, No. 210, October 30.. 1987
Sample IdejiL-fication Analysis Parameters
Proj ect/Site. Stu'/vesant H.S., 345 Chambers .St., NY, NY TEM Samcle No.: 5605 60029
Floors 1-lQ
Date Received: 10/05/31 Grid Openings Analysed:__ 4
Project Sample No. : SHS-1>1 C-10/5-21 Average Grid Opening: 106.00 um
A.ir Volume: Total Area Analyzed: 0.0450 mm2
Filter Tyi'e: MCE 2 5 mm diam., Pore Size: 0.45 um Analytical Sensitivity: ^2 2^2 s/nim2
Effective Area: 3 8 5 rnm2 0.0045 s/cc
FIBROUS PARTICUIATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct > = 5um Strucc/mm2 srruct/cc
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.oooo 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos {Includes amiDiguous structures) 0 0 0.0 0 . 0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/.A
No I de nt i f i c a t ion 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures! 0 0 0.0 0.0000 N/A
The estimated uncertainty o- this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED); None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003473575
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000177642
OCR can misread numbers and units. Confirm readings against the page image before using them.