NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1840
Lab Group #: 7587 Filter Type / Filter Area: MCE 385 mm’
Lab Sample #: 5 Grid Opening Size: 0.01124
Client Sample #: 05 Area Examined: 0.04496 mm-
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: too KeV
# Grid Openings: 4 Analysis Date: 4/30/02
Analysis Performed By: C
MARK PEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or 7 EDS I
(Nonadb i
No F B C M >=05 M ~ >=5|J Chrys Amphibole Nonasb Ambig/ND Elements) I
No Coord <5m
Struct = > 0.5,u >5:1 Aspect Ratio Grid acceptance:
7= Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B ! C M \ >5p
7= EDS spectrum conforming to laboratory holes or opaque areas
Identification criteria obse.n/ed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle ;<3 fibers <1 fibe' diameter apart Crocidolite
Ambiguous [
C = Cluster (>3 Intersections! Anthophyllite Non-Asbestos j
Tremolite
M = Matrix
Actinolite Non-Identified j
NSC = No Structures Detected
I..
CONFIDENTIAL, CITY_21MC100_003471381
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000177143