APPENDIX A Contaminants Not Expected to be Found-Aronnd-the WTC Hazardous Substances Not Recommended for Sampling in Indoor Environment
Benzene
Benzene is a yolatile organic chemical (VOC) that was found in emissions from the open flames and smoldering debris left after the collapse of the WTC. The benzene may haye originated from the airplanes’ residual jet fuel or from the continuous burning of plastics and other materials contained within the collapsed towers.
Since the fires and smoldering debris persisted long after the collapse of the WTC towers, there is a possibility that harmful leyels of benzene yapor could haye accumulated in nearby indoor enyironments. Howeyer, because benzene is yery yolatile and dissipates into ambient air quickly, the yapor plumes would haye had to contain high concentrations of benzene, and the indoor area would haye had to be relatiyely close to the fire source in order for indoor amounts of benzene to build up to harmful leyels. In addition, unlike dioxin, benzene cannot become adsorbed by dust particles and transported indoors to settle as a long-term potential hazard. Once the source of the benzene is extinguished completely from the area, then benzene can no longer be a hazard.
Results of samples taken within the immediate WTC work zone from September II through mid January 2002, show benzene leyels of up to 180,000 parts per billion (ppb). Howeyer, tests during the same time period outside the work zone show leyels of benzene that were below the established EPA screening leyel of 20 ppb, indicating how quickly benzene dissipates in the air. A specific example, for the day of October 3, is shown below;
From debris pile at From debris pile at From Liberty & WTC North Tower WTC South Tower Greenwich Streets 28,000-39,000 ppb 4,300 ppb less than 20 ppb
From January 26, 2002 through April 23, 2002 (the most recent test date ayailable) leyels of benzene in ambient air haye remained below the 20 ppb screening leyel, except for one grab sample from the immediate work zone on February 9 and another sample from the same location on February 12. These tests indicate that the source of harmful ambient benzene leyels has been extinguished, and therefore there is no source of benzene ayailable to accumulate in any indoor enyironment. It is recommended that benzene not be monitored in any further indoor testing.
Polychlorinated Biphenyls (PCBs)
PCBs were historically used as coolants and lubricants in transformers, capacitors, and other electrical equipment. It is possible that, with the collapse of the WTC towers, PCBs could haye been dispersed into the ambient air and then transported indoors. Howeyer, to date, all
20
CONFIDENTIAL, CITY_2IMCl00_003423808 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000176179
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
NYC-WTC_000176140
Appendix document outlining health protective screening values and contaminants of concern for WTC site workers and Lower Manhattan residents.
17 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000162222
EPA staff distributed an environmental laboratory report to federal and city agencies on May 15, 2002.
30 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗30 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
32 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000148952
Table listing volatile organic compound (VOC) sampling sites and dates outside of Ground Zero from September 2001 to January 2002.
29 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160878
EPA notice of chain-of-custody and benchmarks presentation for WTC Taskforce meeting on April 8, 2002.
17 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163599
Draft screening levels for asbestos, fiberglass and silica in indoor air and settled dust.
4 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗18 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164830
DEP internal memo circulating draft EPA screening level standards for asbestos, fiberglass, and silica in indoor air and settled dust for agency comment.
5 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164862
Document introduction describing a cross-agency group tasked with identifying contaminants and establishing health-based screening levels.
17 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151128
Report establishing health-based screening levels for the indoor environment with cross-agency representation.
14 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000162222
EPA staff distributed an environmental laboratory report to federal and city agencies on May 15, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.956 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000162222
EPA staff distributed an environmental laboratory report to federal and city agencies on May 15, 2002.
Similar indexed content
Similar indexed content
Similar indexed content
NYC-WTC_000176140
Appendix document outlining health protective screening values and contaminants of concern for WTC site workers and Lower Manhattan residents.
Similar indexed content
NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similar indexed content