Mr. Bernard P. Orlan June 26, 2002
Wipe Samples fo r Dioxins Page 2
H. S. for Leadership & Public Service (894Mi ATC Project No. 15-19125-0290
This provides a single value (in nanograms) for the analytical results for each sample. The
sample locations and the results are shown in the table.
DIOXIN WIPE SAMPLE RESULTS
(2, 3, 7, 8 TCDD EQUIVALENTS)
May 24, 2002
1 st Floor Main Lobby - Floor /DXl 0.00065
5th Floor Hallway by Elevator - Floor 0.00025
/DX2
IQth Floor Hallway by Elevator - Floor 0.000050
/DX3
The New York State Department of Health (NYSDOH) established guidelines for dioxin for the
re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH
guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^).
The concentrations on indoor surfaces ranged from 0.00005 to 0.00065 nanograms per square
meter (ng/m^). The levels found in all of these samples are below the NYSDOH guideline of 25
ng/m2.
It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in these samples
were deposited. Dioxin samples were not collected from these locations prior to January 2,
2002.
It is our pleasure to provide these indoor environmental services to the NYC Board of Education.
If you have any questions about this report, please call (212) 353-8280, extension 212.
Sincerely,
A TC ASSOCIA TES INC.
Reviewed By:
James R. Cohn, CIH, CSP
Senior Project Manager Regional Manager
Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_21MC100_003432066
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000175639
OCR can misread numbers and units. Confirm readings against the page image before using them.