NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1920
Lab Group #: 8759 Filter Type / Filter Area: MCE 385 mm-
Lab Sample #: II Grid Opening Size: 001124
Client Sample #: 11 Area Examined: 0 04496 mm^
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 8/25/02
Analysis Performed By:
ROMAN PEYSAKHOV
GO Structure Structure Type Length ID of Structure N or V EDS
No (Nonadb
F B C >=05 p >=5p Chrys Amphibole Nonasb Ambig/ND
No Coord <5p Elements)
-
Struct = > 0 5|J >5 I Aspect Ratio Grid acceptance
a/= Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M >5u
• </= EDS spectrum conforming to laboratory boles or opaque areas
identification cnteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle '<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
Tremolite
M = Matrix Non-Identified
Acbnolite
MSD = No Structures Detected
CONFIDENTIAL, CITY_21MC1OO_OO34313O6
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000175511
OCR can misread numbers and units. Confirm readings against the page image before using them.