Wipe sampling report for PCDDs and PCDFs, March 2002

Machine-extracted title · confidence 95%

ATC Associates report on wipe samples for polychlorinated dibenzo-p-dioxins and dibenzofurans collected at a school on February 22, 2002.

NYC-WTC_000175053–000175054
Page image
Scanned page image, NYC-WTC_000175054
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan March 21, 2002 Wipe Samples for Dioxins Page 2 Stuyvesant High School (Manhattan) ATC Project No. 15-19125-0246

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (in nanograms) for the analytical results for each sample. Copies of the draft analysis reports are attached. The results are shown in the following table.

DIOXIN WIPE SAMPLE RESULTS 2, 3, 7, 8 TCDD EQUIVALENTS - Nanograms per square meter (ng/m^) ■^■1

1®^ Floor Lobby Main Entrance / DXl 0.00031 2^ Floor Lobby Bridge Entrance /DX2 0.00015 HVAC #1 Mixed Air Plenum/ DX3 0.00061

Field Blank /DX4 0.0023

The New York State Department of Health (NYSDOH) established guidelines for dioxin for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^). The New York State Department of Environmental Conservation (NYSDEC) has set 0.0006 parts per million (ppm) as the allowable concentration of dioxin in soil. The EPA has established a residential clean-up goal of 1 part per billion (ppb).

The concentrations on indoor surfaces ranged from 0.00015 to 0.00061 nanograms per square meter (ng/m^). The levels found in all of these samples are below the NYSDOH guideline of 25 ng/m^.

It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in this sample was deposited. Dioxin samples were not collected from these locations prior to November 8, 2001, and therefore a background sample is not available for comparison purposes.

It is our pleasure to provide these indoor environmental services to the NYC Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212.

Sincerely, ATC Associates, Im

James R. Cohn CIH, CSP Regional Manager, Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC100_003429588 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000175054

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000175054Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →