NYC 9/11 Public Portal Document
1'
^a»a Materia) PalypfOply«n< Acrylic Polyiulfone
Melling Faint. . 27$«F 210«f ^4*F
- Oeeompoelfion (nan-vlolorttj
Auto l^ltlan S70«.580’F 1022*? (350*CJ
IxtlnguIihMl Media
co,, Dry Chwmlccl, ?o«m Wa1*r Spray
Melting Feint telHnfl Feint
Codmium - 321 •€ 767«C
Cadmium Oxid* UOO’C W'1W*C decamp
NIck«( 1455*C Store
SpiKtal Fire Fi|htlng Praeedurw -
'I
. Lite Mff'conlclned hreathlnfl apdr<rtu», p<oi«c)lv» elotblno ood equipment to prevent potenticl body cantac} ,
with electrolyte eolutloh or mixture of water and lolutlon.
Fire end Jxptoelart Hazard*
Slectrolyfa solution (» corrotNe to oH human tluu**. It will react violently with many orflanlc chemical*, .
J
eepeclaily nltrocorbone and chlorocarbon*. Slecirelyte solution .-ooct* with zine, aluminum, tin anti other active •
moterlol* releOitnp flommOfale hydrojen ga*. '
Cqdmlunt. fume* may be reieated when hotter!** pre lublected to high temoerature*.
6. INORSDISNTS EXPOSURE LIMITS QUANTITY
1 .
Acrylic Folymor Container None ExiobiUhod — OSHA
Folyiulfqne Contolner •None ^obfished — O5HA )0%
Falyprepylane Container None ^obltihed — OSHA
Nickel Oxide, Solid 1 mo/m* — OSHA ■■ 10%
Lithium Hydroxide None Ettabllihed — OSHA < 1%
Ortiphlfe IS mppcf uie r*«plrotor = 3%
Electrolyte Solution 2 mg/m’ ACCIH C€it|NO.A|r * 28% Il
(1S-28Y* pofocsium hydroxide)
Steel None EttoblUhod — OSHA 39%
Cadmium Oxide, Solid 0.1 mg/m’ fume — OSHA 9%
0.2 ma/m* dust — OSHA
o.oa mg/m’ ACOIH Celling
7. PHYSICAL PROPERTIES i.
. Balling Point —. Not Applicable. Melting Point — Net Applicable i'
Vopor Fresswr* —
Specific Gravity —
2 mm Hg at 68’ F
1.180 — .1.280 (eleclrolyte)
Vapor Densify _ Not Applkoble
Evoporollon Rote — Not Delvrmlned
I.
L
Solubility In Water-- Electrolyte solution Is completely soluble. ■ RgMAlNDEft — Is insoluble.
.f ■
8. SPILL MANAGEMENT PROCEDURES i
Ilectrelyte Solutfan Spills c 4
Smell (up te 4 gallon*Jrflutb with waler and neutralize with dilute acid. I
(*•*•«•« ^ekMieele* teb AF O’? t^leMor eot^eselsel 4*^ es^d^. _ „| _____ _____
of storm e^uiis. Recover materiel with vacuum truck and dhpoie of properly. Reporfobie Ovant]ty,~Too6
ii!
». DISPOSAL INPOiWlATION _______ _ J
Th* iforoj* battery I* « botardou* wa»te under RCRA,
Battery is EP Toxic. Battery and sJeCtrolytv solution ore corrosive. Dispose of ft occordonce with all federal, ';
state .end local regulation*. . ' .1
10, PRECAUTIONS AND COMMENTS__________ ________ , _________
. These cells and the batteries constructed from them may be highly active end copoble of rapid generation of
electrical energy. Core should be token to handle celts properly to ovoid shorting or misuse that wtU-result
in ropid uncpntrolied generation at el«ctrlcai, chemical, or hoot energy.
Do.not tronsport octtvoiod bo.tterles without vent cap In place.
When removing battery from service yteualty Inspect hr leakage prior to handling, if leakage has occurred follow
<pM Management Procedures. '.t
Do not otiow on exposed flame or spark to come near the cells._______
Dote issued e *90 i;
OUcioimer: ThU information hoi been complied from sources considered to be d^^ehdoble ond U, te ft* be** of our ir
knawledge and belief, accurate and reliable «* of ft* dote compiled. However, no representotien, warranty {either ?
ejcpreee or implied) or guorontee u mode to ft*' accwrocy, retlobiltty or campUtenet* of ft* infortnatlori contobwd *,
bereft. This Information relate* to the Specific mctenol deelgnatod and mw not be vofid for such materfol used ft \
oembftoilon with any other (noierlds or ft. any pracee*. It Is ft* user’* responsibility ft tofisfy biineetf os ft fto sulftblllly: 1
end oomFletoness of this information ftr bis own ftorlleidar use. We do iftf accept iftbWW for any Io** or domoo* ’
ftotmoyoccur, whether direct. Indirect, ftddeotol orcon^uentlol, fromfteuseof ftfeinftrmaHonnordoweo^ ,
worronft against potent InfrftflementKAddltlona ftformatton 1s available by eolUng ft* telejftone rHrmb«r above.'.
daotgneftd for this purpose.. ' «w*»e»>»s«tiw*«vMoo'j
S'd ■OMI 3JIW ±jes Sl:ST £6. ST^^'
APR 7 '95 10:33
NYC-WTC_000169125
OCR can misread numbers and units. Confirm readings against the page image before using them.