MSDS for DuPont Freon 12 Refrigerant, Oct 1996

Machine-extracted title · confidence 94%

Chemical product identification and safety data sheet for Freon 12 refrigerant including manufacturer contact information.

NYC-WTC_000169087–000169093

Folder label: “7 World Trade Center Blue Prints Haz Mat Info Fire Reports Fire Prevention Records”

Page image
Scanned page image, NYC-WTC_000169089
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

DuPont Suua (310) 575-50Z9 10 10/26/97 21:18 ID:DuP0NT FLUOROCHEnICAL fax:1-302-452-157? PAGE 3

FIRST AID MEASURESiconiinuBU)

Notes to Physicians Because of a possible disturbance of cardiac rhythm, catecholamine drugs, such as epinephrine, should only be used with special caution in situations of emergency life support. ___ _____

FIRE nGHTTNG MEASURES Flammable Properties Flash Point Will not burn Flammable limits in Air, % by Volume LEL Not applicable UEL Not applicable Autoignition >750 C (>1362 F) Fire and Explosion Hazards: Cylinders may rupture under fire conditions. Decomposition may occun_________ ___ _ _ _ Extinguishing Media As appropriate for combustibles in area. Fire Fighting Instructions Use water sprav or fog to cool containers. Self-contained breathing apparatus (SCBA) is required if cylinders rupture and contents are released under fire conditions.

ACCIDENTAL RELEASE MEASURES Safeguards (Personnel) NOTE: Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL) sections before proceeding with clean-up. Use appropriate PERSONALPROTECTIVE EQUIPMENT during Clean-up. Accidental Release Measures Ventilate area, especially low or enclosed places where heavy vapors might collect. Remove open flames. Use self-contained breathing apparatus (SCBA) for large spills.

HANDLING AND STORAGE Handling (Personnel) Use with sufficient ventilation to keep employee exposure- below recommended limits. Storage (llean, dry area. Do not heat above 52 deg C (125 deg F). (Conllnued)

2022FR Pages

NYC-WTC_000169089

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000169089Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DuPont Freon 11 MSDS, November 1996 · Box FDNY

NYC-WTC_000169080

Safety data sheet for Freon 11 refrigerant providing chemical formula and emergency contact details.

3 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.990

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →