NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/7DCAS/Space Analysis by Unit
Document / 6 pages

Space analysis by unit for OEM project 96-1346

Machine-extracted title · confidence 95%

A detailed space analysis sheet dated October 1997 listing personnel counts and square footage for various units at the Office of Emergency Management.

NYC-WTC_000168314–000168319

Folder label: “Space Analysis by Unit

Page image
Scanned page image, NYC-WTC_000168317
OCR text

OCR status: ocr · source: ours

NYC-WTC_000168317 DEPT OF GENERAL SERVICES SPACE DESIGN-PROGRAMMING SPACE ANALYSIS BY UNIT PROJECT#: 96-1346 DATE: 10/20/97 PAGE 3 OF AGENCY: DIVISION: PROGRAM: UNIT (S) Office of Emergency Management (OEM) CURRENT ADDRESS: 100 Church St, 20th Floor New York, NY 10007 BACK-UP SYSTEMS 23rd floor UNIT CODE: All information below are ASSUMPTIONS based upon the information provided thus far; all required to be confirmed and redefined. COMMON & EQUIPMENT AREAS OCCUP. S.F. TOT. COMMON & EQUIPMENT AREAS UPS (UNINTERRUPTED POWER SUPPLY) FUEL TANKS The following are assumptions which need to be confirmed; The building has two 12,000 gallon fuel tanks available to the tenants in bldg. To be located on the agencies main floor- the 23rd floor. Recommendation to use these tanks. To supply the transistion power until the generators start up. With current & estimated pull the tanks would provide adequate fuel for 1 week. Items to be on this back-up system, which can not go down at all include; Exisitng tanks are located underneath the truck docks. EOC Room Watch Command Room PIU Room Computer/LAN Room Mayor's Office Suite Commisioners Office Suite Deputy Directors office Agency Conference Rooms Security System WATER Domestic Water for Building on generator. Recommendation to use building system for domestic water. Agency to store bottled water for all potable water. Estimated water supplies for staff of (125) for 1 week To be stored in the staff kitchen.(no addt'l sf required) Est. size 7.5 sf per 8 bottles (1 bottle per person per week) Radio & Radio Equipment Telephone System UPS to be provided by Telephone vendor. Lights to be on batteries Plumbing not required. Fuel pumps not required. Estimated size unit 100kva Estimated size room (16' x 16') *All sizes are estimates based upon given information. Subject to changes once requirements confirmed. ** Room 1o have special HVAC. *** Structural reinforcement required. All items on the UPS system are ultimately to go on the generator. AIR CONDITIONING The agency requires a fully independant system to support critical areas. During normal operating hours, to use the building systems. Emegency systems required for Watch Command and Computer LAN Rooms. System to be on agency main floor(23rd floor) Washington Street side of building due to louvers. Estimated 75 ton system for critical area emergency system. Estimated size of room is 45' x45' * All sizes are estimates based upon given information. Subject to changes once requirements confirmed. RISER SPACE Riser space available in building core. Require space for emergency power condiuts, fuel and communication condiuts. To be determined once all requirements confirmed. SPACE ANALYST: UNIT PERSONNEL TOTAL PERSONNEL w/CIRC. COMMON/EQUIP. w/CIRC. UNIT GRAND TOTAL S. Lee Wright IAlJefferson INCLUSIVE Carp.Sq.Ft. 2,999 Carp. Sq. Ft. 2,999 Carp. Sq. Ft. S.F. TOT. Sub Total 250 Sub Total 2,000 NYC 9/11 Public Portal Document n/a 2,000 UNKNOWN

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000168317Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Space analysis by unit for OEM project 96-1346 · Box 7DCAS

NYC-WTC_000168320

A detailed space analysis sheet dated October 1997 listing personnel counts and square footage for various units at the Office of Emergency Management.

6 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.991

machine-extracted · confidence unavailable · Check page ↗
OEM space analysis summary sheet, Aug 1997 · Box 7DCAS

NYC-WTC_000170916

Space design and programming summary for Office of Emergency Management including personnel counts and square footage.

6 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.991

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →