NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/7FDNY/No folder label
Document / 26 pages

Fire Department memo on hazardous materials filing requirements, Jan 2001

Machine-extracted title · confidence 95%

Memo from the Fire Department explaining mandatory filing of MSDS and forms for facilities storing hazardous substances.

NYC-WTC_000166458–000166483
Page image
Scanned page image, NYC-WTC_000166462
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Wyuasa MATERIAL SAFETY DATA SHEET Form # 853020

Revised: 4/20/2000 Supersedes; 5/4/1998 Page 1 of 9

1. PRODUCT IDENTIFICATION

Chemical/Trade Name (as used on label): Chemical Family/Classification:

Lead-Acid Battery Electric Storage Battery

Manufacturer's Name/Address Telephone

Yuasa, Inc. For information and emergencies, contact Yuasa’s P.O. Box 14145 Environmental Resources Dept. (610) 208-1975 2366 Bernville Road Reading, PA 19612-4145 24-hour Emergency Response Contact;

CHEMTREC DOMESTIC: 800.424.9300 CHEMTREC INTERNATIONAL: 1.703.527.3887

IL HAZARDOUS INGREDIENTS / IDENTITY INFORMATION

Approximate % Air Exposure Limits (pg/m^) Components CAS Number by Wt. or Vol. PSHA Acom NIPSH Inorganic lead Compound: Lead 7439-92-1 60 50 150 100 * Antimony 7440-36-0 2 500 500 * Arsenic 7440-38-2 0.2 10 200 * Calcium 7440-70-2 0.2 *Tin 7440-31-5 0.2 2000 2000

Electrolyte (sulfuric acid) 7664-93-9 10-30 1000 1000 1000

Case Material: 5-10 N/A N/A N/A Polypropylene 9003-07-0 Polystyrene 9003-53-6 Styrene Acrylonitrite 9003-54-7 Acrylonitrite Butadiene Styrene 9003-56 9 Styrene Butadiene 9003-55-8 Polyvinylchloride 9002-86-2 Polycarbonate Hard Rubber Polyethylene

Other: Silicon dioxide 60676-86-0 N/A N/A N/A (gel batteries only) N/A N/A N/A Sheet Molding Compound (glass reinforced polyester)

• Inorganic lead and electrolyte (sulfuric acid) are the primary componats of every battery manufactured by Yuasa, Inc. Other ingredients may be present dependent upon battery type. Contact your Yuasa representative for additional information.

NYC-WTC_000166462

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000166462Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000132628 · Box DEP Box 54

A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.

Cited alongside this record in an Ask answer

NYC-WTC_000142802 · Box DEP Box 06

Document defining indoor air quality terms such as acid aerosols and action levels for radon remediation.

Cited alongside this record in an Ask answer

Compare copies and versions →