MSDS for DuPont Freon 12 Refrigerant, Oct 1996

Machine-extracted title · confidence 95%

Chemical product identification and safety data sheet for Freon 12 refrigerant including composition details.

NYC-WTC_000166401–000166425
Page image
Scanned page image, NYC-WTC_000166422
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

DuPont Suva (3iB) 575-5029 11 10^26/97 21:19 ID:DuP0NT FLUOROCHEniCAL FAX:1-302-452-157? PAGE 4

EXPOSURE CONTROkS/PERSONAL PROTECTION Engineering Controls Normal ventilation for standard manufacturing procedures is generally adequate. Local exhaust should be used when large amounts are released. Mechanical ventilation should bo used in low or enclosed places. Personal Protective Equipment Impervious gloves and chemical splash goggles should be used when handling liquid. Under normal manufacturing conditions, no respiratory protection is required when using this product. Self-contained breathing apparatus (SC8A) is required if a large release occurs. # Exposure Guidelines Applicable Exposure Limits METHANE, DICHLORODIFLUORO- (“FREON" 12) PEL (OSHA) 1,000 ppm, 4,950 m0/m3, 8 Hr. TWA TLV (ACGIH) 1,000 ppm, 4.950 mg/m3, 8 Hr. TWA, A4 AEL * (DuPont) None Established ‘ AFI is DuHoni's Acceptable exposure Limit. Where governmentally ifliposoo oocupatIonel exposure limits which are lower than the ael are in effect, such limits snail take precedence.

PHYSICAL AND CHEMICAL PROPERTIES Physical Data Boiling Point -29.0 C (-21.6 F) Vapor Pressure 94.5 psia at 25 deg C (7? deg F) Vapor Density 4.26 (Air = 1.0) at 25 deg C (77 deg F) % Volatiles 100 WT% Solubility in Water 0.028 WT% e 25 C (77 F) at 1 atm pH Neutral Odor Slight ethereal Form Liquified gas Color Clear, colorless Density 1.315 g/cc at 25 deg C (77 deg F) • Liquid

STABIUTY AND REACTIVITY Chemical Stability Material is stable. However, avoid open flames and high temperatures. Incompatibility with Other Materials Incompatible with alkali or alkaline earth metals- powdered Al, Zn, Be, etc^.___ ______________ Polymerization Polymerization will not occur. (Conlifiued)

2022FR Page 4

NYC-WTC_000166422

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000166422Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000169137 · Box FDNY

New York State Department of State form requiring businesses to report hazardous materials presence for fire safety compliance.

Similar indexed content

NYC-WTC_000169144 · Box FDNY

Completed state form reporting hazardous material storage locations and quantities at the specified building for fire prevention purposes.

Similar indexed content

NYC-WTC_000169022 · Box FDNY

Memo outlining the requirement for facilities to file MSDSs and forms regarding hazardous substances with the Fire Department.

Similar indexed content

NYC-WTC_000169133 · Box FDNY

New York State Department of State form requiring reporting of hazardous materials at the business address for fire safety compliance.

Similar indexed content

Compare copies and versions →