NYC 9/11 Public Portal Document
DuPont Suva (3iB) 575-5029 11
10^26/97 21:19 ID:DuP0NT FLUOROCHEniCAL FAX:1-302-452-157? PAGE 4
EXPOSURE CONTROkS/PERSONAL PROTECTION
Engineering Controls
Normal ventilation for standard manufacturing procedures is
generally adequate. Local exhaust should be used when large
amounts are released. Mechanical ventilation should bo used
in low or enclosed places.
Personal Protective Equipment
Impervious gloves and chemical splash goggles should be used
when handling liquid. Under normal manufacturing
conditions, no respiratory protection is required when using
this product. Self-contained breathing apparatus (SC8A) is
required if a large release occurs.
# Exposure Guidelines
Applicable Exposure Limits
METHANE, DICHLORODIFLUORO- (“FREON" 12)
PEL (OSHA) 1,000 ppm, 4,950 m0/m3, 8 Hr. TWA
TLV (ACGIH) 1,000 ppm, 4.950 mg/m3, 8 Hr. TWA, A4
AEL * (DuPont) None Established
‘ AFI is DuHoni's Acceptable exposure Limit. Where governmentally ifliposoo oocupatIonel exposure
limits which are lower than the ael are in effect, such limits snail take precedence.
PHYSICAL AND CHEMICAL PROPERTIES
Physical Data
Boiling Point -29.0 C (-21.6 F)
Vapor Pressure 94.5 psia at 25 deg C (7? deg F)
Vapor Density 4.26 (Air = 1.0)
at 25 deg C (77 deg F)
% Volatiles 100 WT%
Solubility in Water 0.028 WT% e 25 C (77 F) at 1 atm
pH Neutral
Odor Slight ethereal
Form Liquified gas
Color Clear, colorless
Density 1.315 g/cc at 25 deg C (77 deg F) •
Liquid
STABIUTY AND REACTIVITY
Chemical Stability
Material is stable. However, avoid open flames and high
temperatures.
Incompatibility with Other Materials
Incompatible with alkali or alkaline earth metals- powdered
Al, Zn, Be, etc^.___ ______________
Polymerization
Polymerization will not occur.
(Conlifiued)
2022FR Page 4