NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/7FDNY/No folder label
Document / 235 pages

NYC-WTC_000166105

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000166105–000166339
Page image
Scanned page image, NYC-WTC_000166124
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

N/A YES NO SUMMONS/ NOV # F. RECORDS: 1. FIRE DRILLS CONDUCTED AND RECORDED (DATE OF LAST ) 6O 2. SMOKE DETECTORS CLEANED AND TESTED, LOG MAINTAINED 3. ALARM LOG BOOK MAINTAINED 4. MONTHLY TEST RECORD OF FIREMEN'S SERVICE ELEVATORS ~~~ C(ib''►~ 5. MONTHLY TEST RECORD OF CLASS "E" F.A.C.S. 6. MONTHLY TEST RECORD OF FIRE PUMPS (IF REQUIRED) 6, Zs~ro 7. MONTHLY TEST RECORD OF EMERGENCY GENERATOR (IF REQUIRED) 8. MONTHLY RECORD OF SPRINKLER .INSPECTION b isJo 9. MONTHLY RECORD OF STANDPIPE INSPECTION G. FIRE PROTECTION SYSTEMS: 1. C OF F SPRINKLER ( ✓ ) NAME NO.b) a? 2. SPRINKLER VALVE SEALED OPEN (SUMMONS IF CLOSED) 3. SPRINKLER SIAMESE SWIVEL ( '-1 UNOBSTRUCTED ( SIGN IF REQUIRED ( k' °' 4. COFFSTANDPIPE(✓)NAME "^" NO.b° O 5 5. STANDPIPE VALVES SEALED OPEN ~ ~ ~~-i `' ''' ' tC' S 6. STANDPIPE SIAMESE: SWIVELS ( UNOBSTRUCTED ( ✓) 7. EXTINGUISHERS PROPERLY HUNG AND DISTRIBUTED 8. EXTINGUISHERS TAGGED: DATE OF LAST INSPECTION ( ,2) t'- ) H. SIGNS: 1. ELEVATOR: LETTER DESIGNATION ( '-ii. DIAGRAM "IN CASE OF FIRE USE STAIRS" ( ) 2. STAIR: FLOOR NO. ( LETTER DESIGNATION-OCCUPANCY SIDE ( -STAIR SIDE 3. RE-ENTRY SIGNS POSTED 4. EXIT AND DIRECTIONAL SIGNS ILLUMINATED 5. ORGANIZATIONAL_ CHARTS POSTED AND ACCURATE I. GENERAL: 1. CERTIFICATE OF OCCUPANCY POSTED ja t 2. ALL AREAS FREE OF RUBBISH a PAPER RECYCLING HAMPERS STORED IN PROPER LOCATION (NOT IN HALLWAYS OR ELEVATOR LOBBIES) 4. STAIRWAY DOORS OPENABLE AT ALL TIMES (OCCUPANT SIDE) (IF NO: APPROVED BY D.O.B. h_ CONNECTED TO CLASS "E" 5. RE-ENTRY PROVIDED WHERE REQUIRED a. FAIL SAFE SYSTEM ( 1INDICATE FLS. ( 4 L-L.- 6. IF SHAFTS PRESENT (i.e., ELEC. CLOSETS) ARE THEY FIRESTOPPED 7. FLOOR WARDENS. DEPUTY WARDENS, AND SEARCHERS TRAINED a. FLOORS CHECKED ( l l3 , 17- L-pbbl ) I 3. F1_=.`'MABLES/COMBUSTI5LES PROPERLY STORED a. _-CATlC x )l J 4--Tb1eS

NOV ITOTAL'SUMMONS IT"TAL:'Tci4S: —."1.

NYC-WTC 000166124

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000166124Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

FDNY CIDS form for 7 World Trade Center · Box FDNY

NYC-WTC_000169164

A Critical Information Dispatch System (CIDS) form from the Fire Department containing building data and contact information for 7 World Trade Center.

2 shared non-person entities · similarity 0.969

machine-extracted · confidence unavailable · Check page ↗

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165980 · Box 7FDNY

Official violation order document issued by the FDNY Bureau of Fire Prevention directing correction of safety violations at a premises.

Similar indexed content

NYC-WTC_000166000 · Box 7FDNY

Official violation order document issued by the FDNY Bureau of Fire Prevention directing correction of safety violations at a premises.

Similar indexed content

NYC-WTC_000169205 · Box FDNY

Document summarizing fire service activities or inspections performed at the specified location.

Similar indexed content

Compare copies and versions →