+ 1
I I > 40 ug/ft2 or 1,200 ppm | aggressive cleaning I
1 1 (professional?) - if 1
I I readings persist take I
I I additional action to reduce 1
1 1 exposure 1
+ +-------------------------- 1
II I 400 - 1,200 ppm 1 maintain recommended (i.e., |
1 I diligent wet/HEPA) cleaning |
I 1 methods - consider I
I I additional monitoring
+-------------------- I
III I <40 ug/ft or 400 ppm 1 no further action I
+-------------------- I
Lead (indoor air)
----- + +
Tier I Screening Value I Action
+
I I >1.5 ug/m3 (NAAQS) aggressive cleaning |
1 (professional?) - if |
1 readings persist take |
I additional action to reduce 1
I exposure |
'+
I II I background - 1.5 ug/m3 I maintain recommended (i.e.,
I I I diligent wet/HEPA) cleaning
I I I methods - consider
I I 1 additional monitoring
1 .+-------------------------
I III I < background 1 no further action
■+--------------------------------------------------------
I
3
NYC-WTC_000163609
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000163609Source: NYC Law Department, mirrored locally
EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.