J1 Cleaning Procedttres For 125 Cedar Street
Action Item / Notables Unit No. • Built-in air conditioning unit to be evaluated by the project monitor to determine proper cleaning or disposal methods, • The wood burning stove is to be cleaned by wet wiping and HEPA vacuuming. Compressed dry air (low pressure) shall be used to blow debris/dust from openings/crevices. HEPA vacuuming Penthouse must be preformed in conjunction with this procedure. The chimney shall be cleaned to the exhaust point. • The wooden chest is bolted in place; it can be unbolted for cleaning. • Wooden decking shall be cleaned afier consultation with tenant.__________________________ • Wall-mounted carpeting shall be cleaned in accordance with the carpet procedures specified 12SE herein. ______________________________________________________________________ • Interior of chimney flue leading to the roof shall be cleaned. • Living room walls shall not be wet wiped. ns • Bureau shall be cleaned after consultation with tenant. • Painting behind bed shall not be handled.____________________________________________ • The crawlspace located in the bathroom shall be cleaned. If demolition is required to access this crawlspace, the contractor shall provide the demolition. The contractor is not responsible IOS for floor replacement. • An isolation barrier shall be installed over the closet with boxes. Boxes shall not be handled or cleaned._______________________________________________________________________ • North column wall to be removed. 8N • Stored moldinzs shall be cleaned afier consultation with tenant.__________________________ • The jukebox shall be cleaned. Compressed dry air (low pressure) shall be used to blow TN debris/dust from openings/crevices in these items. HEPA vacuuming must be preformed in conjunction with this procedure. Care must be taken not to damage the items._______________ • The piano shall be cleaned. Compressed dry air (low pressure) shall be used to blow debris/dust from openings/crevices. HEPA vacuuming must be preformed in conjunction with 5N this procedure. Care must be taken not to damage the piano. This procedure shall be repeated until the piano is appropriately clean as determined by the project monitor. • Radiator covers shall be removed and discarded.______________________________________ • Knitting machines shall be cleaned. Yam on the machine shall be disposed. Compressed dry air (low pressure) shall be used to blow debris/dust from openings/crevices. HEPA vacuuming must be preformed in conjunction with this procedure. Care must be taken not to damage the 3N machines. This procedure shall be repeated until the machines are appropriately clean as determined by the project monitor. • Artwork shall be cleaned after consultation with tenant. • Slides shall be cleaned after consultation with tenant.__________________________________ 3S • The painting shall be covered without cleaning it.
5 of 6
NYC-WTC_000163437
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
13 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000156006
Internal communication confirming receipt of Department of Health mold assessment report for 125 Cedar.
20 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107535
Resident request for DEP to perform cleaning and monitoring work at an apartment in Manhattan.
18 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107169
Letter from DEP responding to an inquiry by enclosing scopes of work for environmental cleanup at 125 Cedar Street.
19 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107379
Formal request by a resident for the Department of Environmental Protection to perform cleaning and monitoring work at their apartment.
20 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107814
Document listing seven contractor companies authorized for asbestos removal and cleanup operations at the WTC site.
20 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155880
Document outlining requirements for a consultant to provide full-time asbestos air monitoring during the interior cleaning of 125 Cedar.
11 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗13 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
12 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 110 Liberty Street · 1 pages · confidence 0.00 · verify page 7
- 125 Cedar Street · 6 pages · confidence 0.15 · verify page 1
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000163228
Official notice instructing staff to preserve scanned World Trade Center documents as potential evidence in future legal actions.
Filed in the same folder
NYC-WTC_000163229
Official directive instructing staff to retain specific scanned WTC documents as evidence for potential future litigation against the City.
Filed in the same folder
NYC-WTC_000163231
Interdepartmental comments from NYCDOH and NYSDOH on draft Statements of Work for WTC contracts.
Filed in the same folder
NYC-WTC_000163234
EPA correspondence clarifying regulatory agency roles, asserting NYC Department of Health holds primary authority for mold remediation in WTC recovery.
Filed in the same folder
NYC-WTC_000163238
EPA transmission of finalized Scopes of Work for indoor dust cleaning and environmental monitoring components of recovery program.
Filed in the same folder