NYC 9/11 Public Portal Document
made on tihe basis of a visual inspection. In addition, air-sampling methods
for some fungi are prone to false negative results and therefore cannot be
used to definitively rule out contamination.
e. Air monitoring may be necessary if an individual(s) has been diagnosed
with a disease that is or may be associated with a fungal exposure (e,g,,
pulmonary hemorrhage/hemosiderosis, and aspergillosis).
f. Air monitoring may be necessary if there is evidence firom a visual
inspection or bulk sampling that ventilation systems may be contaminated.
The purpose of such air monitoring is to assess the extent of contamination
throughout a building. It is preferable to conduct sampling while
ventilation systems are operating.
g- Air monitoring may be necessary if the presence of mold is suspected
(e.g., musty odors) but cannot be identified by a visual inspection or bulk
sampling (e.g., mold growth behind walls). The purpose of such air
monitoring is to determine the location and/or extent of contamination.
h. If air monitoring is performed, for comparative purposes, outdoor air
samples should be collected concurrently at an air intake, if possible, and
at a location representative of outdoor air. For additional information on
air sampling, refer to the American Conference of Governmental
Industrial Hygienists' document, "Bioaerosols: Assessment and Control,"
1. Personnel conducting the sampling must be trained in proper air sampling
methods for microbial contaminants, A laboratory specializing in
mycology should be consulted for specific sampling and shipping
instructions.
2.4 Analysis of Environmental Samples
Microscopic identification of the spores/colonies requires considerable
expertise. These services are not routinely available from commercial
laboratories. Documented quality control in the laboratories used for
analysis of the bulk/surface and air samples is necessary. The American
Industrial Hygiene Association (AIHA) offers accreditation to microbial
laboratories (Environmental Microbiology Laboratory Accreditation
Program (EMLAP)). Accredited laboratories must participate in quarterly
proficiency testing (Environmental Microbiology Proficiency Analytical
Testing Program (EMPAT)).
NYC-WTC_000163391
OCR can misread numbers and units. Confirm readings against the page image before using them.