11 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗E-mails M. Gilsenan
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000163260–000163271
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Cleaning Procedures 7’ For
pf 125 Cedar Street
(18) The project monitor shall perform a thorough visual inspection to verify the absence of visual dust accumulations. Additional clean-up procedures shall be performed where visible dust is observed.
(19) Upon successful visual inspection, the work area shall be isolated from the remainder of the work site pending clearance air monitoring. Clearance air monitoring shall be performed after completion of all clean up activities at the work site. (20) The Air Sampling Technician shall perform air sampling after the area is free of dust accumulations as determined by the Project Monitor. The apartment will be re-cleaned and retested if the air monitoring clearance criteria are not achieved. The clearance air monitoring criteria have been established by the USEPA for this clean up activity (WTC vicinity). The monitoring contractor shall also collect wipe samples for metals. Refer to the monitoring specification for additional information.
(21) After successful clearance air monitoring, isolation barriers shall be removed in accordance with the applicable requirements of Title 15, Chapter 1 of the RCNY.
(22) The cleaning contractor is not responsible for damage or loss caused by the acts of parties not involved with the cleanup. Tenant shall be responsible for the removal of any valuables. If such removal is not feasible, the tenant shall notify the Project Monitor in writing (including original receipt, formal appraisal, or estimated value) as to the location, description and value of said item.
(23) Disposal of all waste generated during the cleaning shall be the responsibility of the contractor. All waste generated shall be treated as asbestos-containing material (ACM) unless otherwise indicated herein. Transportation and disposal of generated waste shall be in compliance with all applicable rules and regulations. (24) AU work shall be in compliance with all other applicable requirements of Title 15, Chapter 1 of the RCNY. (25) Visible mold has been verified in apartments 6N, 5N, 4N, 3N and 2N. The contractor shall cut and remove all portions of sheet rock with the presence of mold. The abatement contractor shall not be responsible for repair or replacement of removed sheet rock. For other surfaces, the cleaning contractor shall perform necessary remediation with additional guidance fi-om NYC DEP and NYC DOH. Staff experienced in mold remediation is required. The contractor may subcontract this portion of the work. (26) The following table contains special conditions and handling instructions for items in specific units. Items not specifically referenced in this table shall be cleaned in accordance with the procedures specified in this scope of work.
4 of 6
NYC-WTC_000163269
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
7 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
10 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155880
Document outlining requirements for a consultant to provide full-time asbestos air monitoring during the interior cleaning of 125 Cedar.
11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155990
Detailed procedures for interior remediation at 125 Cedar including EPA air monitoring specifications.
11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153551
Resident requests DEP cleaning and monitoring at 125 [name] following WTC collapse debris accumulation.
11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156006
Internal communication confirming receipt of Department of Health mold assessment report for 125 Cedar.
11 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107169
Letter from DEP responding to an inquiry by enclosing scopes of work for environmental cleanup at 125 Cedar Street.
12 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107535
Resident request for DEP to perform cleaning and monitoring work at an apartment in Manhattan.
11 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155872
Application requesting approval for a licensed contractor to clean debris and dust from the building's interior.
11 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 110 Liberty Street · 1 pages · confidence 0.00 · verify page 7
- 125 Cedar Street · 8 pages · confidence 0.15 · verify page 6
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000163228
Official notice instructing staff to preserve scanned World Trade Center documents as potential evidence in future legal actions.
Filed in the same folder
NYC-WTC_000163229
Official directive instructing staff to retain specific scanned WTC documents as evidence for potential future litigation against the City.
Filed in the same folder
NYC-WTC_000163231
Interdepartmental comments from NYCDOH and NYSDOH on draft Statements of Work for WTC contracts.
Filed in the same folder
NYC-WTC_000163234
EPA correspondence clarifying regulatory agency roles, asserting NYC Department of Health holds primary authority for mold remediation in WTC recovery.
Filed in the same folder
NYC-WTC_000163238
EPA transmission of finalized Scopes of Work for indoor dust cleaning and environmental monitoring components of recovery program.
Filed in the same folder