DRAFT COC Airborne Screening Levels April 1,2002
Asbestos - all types taken together
Level Recommended actions Comments
Air level: Evaluate the need to remove Screening value in air set at a level
>0.01 ficc * sensitive individuals fiom the where short term exposures (< 1 year)
environment may result in exposures which
contribute to
Evaluate conditions in the area
Settled Dust level: including representativeness of air Settled dust threshold is to protect to at
> 100, fi'cm^ samples, fibrous glass dust levels least a 1X10"* risk estimate for a one
and loading. year exposure. Air concentrations
estimated for different activities using
Take actions to reduce exposures. a K factors based on Millette’s work
- clean area on asbestos. Risk estimate is based on
- resample estimates of air levels, and duration of
- ongoing cleaning exposure for different activities.
(100, 7cm2 corresponds to a 3x10-
5 risk for a one year exposure)
Air level: Evaluate conditions in the area For those areas where air levels would
NYC background including representativeness of air not warrant removal of sensitive
- 0.01 f/cc * samples, fibrous glass dust levels individuals, but are above the 0.001
and loading. f/cc, continued cleaning and evaluation
Or is prudent.
Settled Dust level: If air samples were not taken, then Settled dust threshold is to protect to at
appropriate air sampling should be least a 1X10"* risk estimate for a 30
10,1 fZcm^ conducted to determine if fiber year exposure. Air concentrations
To levels are elevated. estimated for different activities using
100, f'cm^ a K factors based on Millette’s work
Take actions to reduce exposures. on asbestos. Risk estimate is based on
- clean area estimates of air levels, and duration of
- resample exposure for different activities.
- ongoing cleaning (10,1 fZcm2 corresponds to a 1x10-4
risk for a 30 year exposure)
Air level: No action required
<NYC
background
And
Settled Dust level:
< background
or 1 fi'cm^
* Fibers with length > 5/zm with an aspect ratio 3:1, as defined in the ACGIH TLV.
NYC-WTC_000160812