Interior cleaning scope of work for 125 Cedar, August 2002

Machine-extracted title · confidence 85%

Detailed procedures for interior remediation at 125 Cedar including EPA air monitoring specifications.

NYC-WTC_000155990–000155996

Folder label: “125 CEDAR 1 OF 2

Page image
Scanned page image, NYC-WTC_000155996
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Cleaning Procedures For 11 125 Cedar Street

Unit No. Action Item/Notables______________________________________________________ • Suspended ceiling tiles and ductwork to be removed and disposed. • Stove exhaust duct to be cleaned and left in place • Remove all hung ceiling supports and tiles, and dispose • Demolish rigid ceilings and dispose Lobby • Demolish ceiling mounted air-handler(s) and dispose (Restaurant) • Remove and demolish all associated sheet metal and flex-duct, including thermal insulation Two (2) kitchen exhaust hood systems were also present in the restaurant. A through cleaning of these systems would restore them to a useable condition. Traditional kitchen exhaust hood cleaning practices as prescribed by the International Kitchen Exhaust Cleaning Association (IKECA) could be used for this purpose.

(27) Time sheets shall be submitted to NYC DEP on a weekly basis.

(28) At the completion of work a final report shall be submitted to NYC DEP. The final report shall include copies of the daily logs (activities and entry/exit logs), waste manifests, etc.

6 of 6

NYC-WTC_000155996

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000155996Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →