11 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Form specifying air monitoring consultant services for 125 Cedar, Aug
Machine-extracted title · confidence 90%Document outlining requirements for a consultant to provide full-time asbestos air monitoring during the interior cleaning of 125 Cedar.
NYC-WTC_000155880–000155887Folder label: “125 CEDAR 1 OF 2”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Cleaning Procedures For
Action Item I Notables Unit No. • Built-in air conditioning unit to be evaluated by the project monitor to determine proper cleaning ordisposal methods. • The wood burning stove is to be cleaned by wet wiping and HEPA vacuuming. Compressed dry air (low pressure) shall be used to blow debris/dust from openings/crevices. HEPA vacuuming Penthouse must be preformed in conjunction with this procedure. The chimney shall be cleaned to the exhaust point. • The wooden chest is bolted in place; it can be unbolted for cleaning. • Wooden decking shall be cleaned after consultation with tenant. 12SE • Wall-mounted carpeting shall be cleaned in accordance with the carpet procedures specified herein. • Interior of chimney flue leading to the roof shall be cleaned. 11 S • Living room walls shall not be wet wiped. • Bureau shall be cleaned after consultation with tenant. • Painting behind bed shall not be handled. • The crawlspace located in the bathroom shall be cleaned. If demolition is required to access this crawlspace, the contractor shall provide the demolition. The contractor is not responsible l OS for floor replacement. • An isolation barrier shall be installed over the closet with boxes. Boxes shall not be handled or cleaned. • North column wall to be removed. 8N • Stored moldings shall be cleaned after consultation with tenant. • The jukebox shall be cleaned. Compressed dry air (low pressure) shall be used to blow 7N debris/dust from openings/crevices in these items. HEPA vacuuming must be preformed in conjunction with this procedure. Care must be taken not to damage the items. • The piano shall be cleaned. Compressed dry air (low pressure) shall be used to blow debris/dust from openings/crevices. HEPA vacuuming must be preformed in conjunction with 5N this procedure. Care must be taken not to damage the piano. This procedure shall be repeated until the piano is appropriately clean as determined by the project monitor. • Radiator covers shall be removed and discarded. • Knitting machines shall be cleaned. Yam on the machine shall be disposed. Compressed dry air (low pressure) shall be used to blow debris/dust from openings/crevices. HEPA vacuuming must be preformed in conjunction with this procedure. Care must be taken not to damage the 3N machines. This procedure shall be repeated until the machines are appropriately clean as determined by the project monitor. • Artwork shall be cleaned after consultation with tenant. • Slides shall be cleaned after consultation with tenant. 3S • The painting shall be covered without cleaning it.
5 of 6
NYC-WTC 000155885
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
Filed elsewhere
11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155990
Detailed procedures for interior remediation at 125 Cedar including EPA air monitoring specifications.
11 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153551
Resident requests DEP cleaning and monitoring at 125 [name] following WTC collapse debris accumulation.
11 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186733
Permit application for licensed asbestos abatement contractor to clean debris from interior of 125 Liberty Street.
11 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107169
Letter from DEP responding to an inquiry by enclosing scopes of work for environmental cleanup at 125 Cedar Street.
11 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156006
Internal communication confirming receipt of Department of Health mold assessment report for 125 Cedar.
11 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107535
Resident request for DEP to perform cleaning and monitoring work at an apartment in Manhattan.
10 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107814
Document listing seven contractor companies authorized for asbestos removal and cleanup operations at the WTC site.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108828
Regulatory specifications for asbestos abatement work including PPE requirements and decontamination systems at 125 [name].
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107808
Permit application for asbestos abatement contractor to clean interiors of a building at 125 [name].
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107379
Formal request by a resident for the Department of Environmental Protection to perform cleaning and monitoring work at their apartment.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 110 Liberty Street · 1 pages · confidence 0.00 · verify page 2
- 125 Cedar Street · 6 pages · confidence 0.15 · verify page 1
- 80 Centre Street · 1 pages · confidence 0.15 · verify page 8
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000096827
Document identified only by its archive reference number with no visible text content in the excerpt.
Cited alongside this record in an Ask answer
Letter from DOHMH transmitting results of a July 2002 mold inspection at 125 Liberty Street.
Cited alongside this record in an Ask answer
Cited alongside this record in an Ask answer
Cited alongside this record in an Ask answer
NYC-WTC_000139360
DEP official asks if new mold regulations require inclusion in the cleaning scope for 125 Cedar Street.
Cited alongside this record in an Ask answer