NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 31/114 LIBERTY 1 OF 2
Document / 4 pages

EPA letter re: Clearance results for 114 Liberty Street, Apr

Machine-extracted title · confidence 50%

EPA confirms that primary and secondary clearance levels for contaminants at 114 Liberty Street have been met.

NYC-WTC_000154940–000154943

Folder label: “114 LIBERTY 1 OF 2

Page image
Scanned page image, NYC-WTC_000154942
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

0.0009 s/cc. No additional cleaning is required for asbestos. All of the areas met the primary clearance level for asbestos’.

Lead - Thirty pre-cleaning wipe samples were collected and analyzed for lead at a detection limit of 20 pg/fP. Thirteen simples were above 25 gg/tf and represent apartments on the 10* floor (2 of 3 above 25 pg/tf), 9* floor (2 of 3 above 25 fig/ff^), 7* floor (1 of 3 above 25 fig/f^), 5* floor (2 of 3 above 25 pg/tf), 4* floor (2 of 3 above 25 fig/f^), 3*^ floor (1 of 3 above 25 gg/ft’), and 11* floor (3 of 6 above 25

Thirty post-first cleaning wipe samples were collected from each floor and analyzed for lead at a detection limit of 9 /ig/ft^. AU of the sample results were below 25 fig/fl^. Post-cleaning concentrations from areas that had pre-cleaning concentrations above 25 fig/fi^ were all below the primary clearance value. No additional cleaning required for lead. AU of the areas met the primary clearance level for lead.

Dioxin - Thirty pre-cleaning wipe samples collected and analyzed for dioxin. The maximum Toxicity Equivalents (TEQ) Estimated Maximum Potential Concentration (EMPC) with non-detects equal to 54 of the detection limit (ND=l/2) value was 0.951 ng/m^. This sample and the remaining 29 samples were all below the primary clearance value of 4 ng/m’. Based on the pre-cleaning samples, no additional cleaning required for dioxin.

Thirty post-cleaning wipe samples collected and analyzed for dioxin. The maximum TEQ EMPC (ND=l/2) value was 0.837 ng/m^. This sample and the remaining 29 samples were all below the primary clearance value of 4 ng/m^. Based on the post-cleaning samples, no additional cleaning required for dioxin. AU of the areas met the primary clearance level for dioxin.

PAHs - Thirty pre-cleaning wipe samples collected and analyzed for PAHs at a detection limit of 1 fig. Allot fte fosulte were below the detection limit and the calculated Toxicity Equivalent Factors (TEFs) for each sample was 116 fig/m^, which is below the primaiy clearance level of300 fig/m^. Based on the pre­ cleaning samples, no additional cleaning is required for PAHs.

Thirty post-cleaning wipe samples collected and analyzed for PAHs at a detection limit of 1 fig. All or the resuite were below the detection limit and the calculated TEFs for each sample was 116 ;ig/m^, which is below the primary clearance level of300 fi^ra^. Based on the pre-cleaning samples, no additional cleaning is required for PAHs. AU of the areas met the primary clearance level for PAHs.

Fibrous glass - Sixty-five air samples were collected and analyzed for fibrous glass. All of die samples were below the secondary clearance level of 0.01 fi'cc. In addition, all of the PCM analyses were below the 0,01 f/cc. PCM analysis results provide another data set that can be used to assess fibrous glass, with the assumption that all detected fibers are fibrous glass, and the PCM data set for 114 Liberty indicates that even if all the fibers from the PCM analysis were fibrous glass, all samples would be below the secondary clearance level of 0,01 free. All of the areas met the secondary clearance level for fibrous glass.

Silica - Eleven air samples were collected and analyzed for crystalline silica at a detection limit of 1 Ipg/m’. Seven samples were below the detection limit and four samples were above the detection limit, with values of 17.2,19.6,22.1, and 22.Tpg/m^. The numeric criterion that USEPA has proposed in the

’ This conclusion does not include the area that contains the pizza shop. As discussed in the letter and die summary of the data, the pizza shop contains asbestos-containing material (ACM) that is in poor condition. The ACM will be addressed through an asbestos abatement project.

NYC-WTC_000154942

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000154942Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →