NYC 9/11 Public Portal Document
10. A minimum of one asbestos supervisor shall be present in each building during work.
11. A Cleaning Checklist (to be developed by EPA) will be completed by the cleaning
contractor as tasks are completed to document the progress of the cleaning.
12. The cleaning contractor shall notify the monitoring contractor immediately upon
completion of the cleaning. The Monitoring Contractor will conduct a thorough visual
inspection to verify the absence of visible dust accumulations. If dust is observed the
cleaning contractor will reclean as necessary at no additional cost.
13. Air sampling shall be performed by the Monitoring Contractor after the area is free of dust
accumulations as determined by the Monitoring Contractor. The residence will be
recleaned and retested if the clean-up criteria of 0.0009 fibers/cc (PCME measured by
TEM) is not achieved or if determined necessary by EPA. This clean-up criterion may be
reevaluated and revised, if determined necessary based on field conditions and analytical
limitations.
14. Any damage or loss that occurs during cleaning is the responsibility of the cleaning
contractor. The cleaning contractor is not responsible for damage or loss caused by the acts
of third parties not involved in the cleaning activities.
15. Residents may identify and tag certain furnishings (e.g. carpets and fabric covered
furniture) for disposal rather than cleaning. Disposal of residents’ personal property shall
not occur without prior written authorization by the owner.
16. Disposal of all wastes generated during the cleaning shall be the responsibility of the
contractor. All waste generated shall be treated as asbestos-containmg material (ACM).
Transportation and disposal of generated waste shall be in compliance with all applicable
rules and regulations.
17. If mold, suspected ACM or peeling, flaking or chalking paint is observed in the work
area, the cleaning contractor shall immediately contact the Monitoring Contractor.
6
NYC-WTC_00bT54313
OCR can misread numbers and units. Confirm readings against the page image before using them.