NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 11/WTC DC TO RC LETTERS CALLEHAN WHITMAN ETC. WARD DOCTOROFF KENNY
Document / 3 pages

Memo on asbestos dust sampling methods debate, May 2002

Machine-extracted title · confidence 95%

A letter addressing industry debates regarding the reliability of microvacuum and wipe techniques for asbestos sampling.

NYC-WTC_000151393–000151395

Folder label: “WTC DC TO RC LETTERS CALLEHAN WHITMAN ETC. WARD DOCTOROFF KENNY

Page image
Scanned page image, NYC-WTC_000151395
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

>

In 1999, the ASTM issued a standard test method for wipe sampling of surfaces. The limitations of this test method were similar to the limitations indicated for the microvacuum technique. This method also has not been adopted by any State or local regulatory agency. I I A single direct relationship between asbestos-containing dust and potential human exposure has not been established. Although, a direct relationship between dust levels and exposure has been I documented for other contaminants, including lead, this relationship has not been documented I for asbestos fibers probably due to the unique aerodynamic aspects of asbestos fibers. I I The scientific community is split on the use of a k-factor for evaluating the relationship between asbestos-containing dust and potential human exposure. The k-factor is expressed as the amount of asbestos in a volume of air divided by the amount of asbestos in the surface dust. The k-factor is a fimction of surface type, physical activity and the composition of the dust. The application of the k-factor to the response actions for the WTC is therefore questionable.

The circulation of air in conjunction with air sampling provides direct information on potential exposure. Asbestos is primarily an inhalation hazard that has been associated with lung cancer, mesothelioma, and asbestosis. The information is well established and is the basis for clearance air sampling in regulatory standards.

Clearance air monitoring following an asbestos removal project requires the use of forced air equipment to reentrain settled asbestos fiber and the collection of air samples during air circulation procedures. This methodology provides a direct evaluation of cleaning activities and has promulgated clearance criteria.

Individuals are trained and certified for collection of air and bulk samples. The training and certification requirements include units on hazard assessment, selection of sampling locations, and proper sample collection of air and bulk materials. Individuals are not uniformly trained or certified for collection of asbestos dust samples.

Further, conversations with the New York State Department of Health indicate that asbestos dust sampling and analysis procedures have not been adopted due to the lack of precision. Laboratories participating in the Environmental Laboratory Approval Program are not accredited to perform dust sample analysis. Reported results of dust sample analysis must indicate the laboratory is not accredited for the performance of the analysis.

NYC-VVTC_000151395

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000151395Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →