NYC 9/11 Public Portal Document
Mr. Vincent McGowan
BPCPC
January 14, 2001
Page 2 of2
4 ♦ -,4
Colden collected four composite bulk soil samples from the planters and the areas underneath
the play structure in the park as well as a total eight surface wipe samples from various contact
areas in the park.
The composite bulk soil samples were collected from five sub locations at each sample
location, combined in one sample container and mixed thoroughly to create each composite
sample.
The bulk composite soil sample locations are as follows;
1. Raised Planter - North End of Park
2. Raised Planter - South End of Park
3. Play Structure - East Side
4. Play Structure - West Side
The wipe samples were collected at four locations with two s de-by-sids samples collected at
each location. This side-by-side sampling was necessary due to the two distinct analytical
methods required for the wipe samples. The surface wipe sample locations are as follows;
1. Stainless Steel Water fountain - North End of Park
2. Yellow Plastic Slide on Play Structure (at base of slide)
3. Metal Slide on Play Structure (at base of slide)
4. Concrete Footing Pad for Play Structure - North .End of Play Structure
Sample Analj-sis
The soil samples were analyzed for the presence of a.sbestcs fibers utilizing Polarized Light
Microscopy (PLM) analysis. In addition, these soil samples were analyzed for the presence
eight elemental metals Imown as th.e RCRA metals. (Arsenic, Barium, Cadmium, Cliromium,
Lead, Mercury, Selenium and Silver). This was performed using Inductively Coupled Plasma
(ICP) analvtical methods.
The surface wipe samples were, analyzed for Arsenic, Cadmium, Chromium and Lead in one
sample set and Mercury in a separate sample set.
The asbestos samples were analyzed by Scientific Laboratories, Inc. (Sci Lab) of New York,
New York. Sci Lab’s New York laboratory is certified under the. New York State Department
of Health (NYSDOH) Environmental Laboratory Approval Program (ELAP #11480) for the
analysis of asbestos bulk samples.
t?0’d ££:60 200£-92-abW
NYC-WTC_000150469
OCR can misread numbers and units. Confirm readings against the page image before using them.