NYC 9/11 Public Portal Document
Staten Island Landfill Debris Disposal Operation Health and Safety Program
Direct reading instruments and colormetric detector tubes may be used to screen
work activities for chemical parameters. While a useful tool for establishing sampling
parameters, this types of sampling will not be used to establish negative exposure
assessments.
Whole shift monitoring - This typically is based on an 8 hour work shift, since OSHA exposure limits
often are based on an 8 hour time-weighted average. The subject work operation involves shifts of
12 hour shifts rather than 8 hours, and will require that exposure samples be collected over a 12
hour period. The interpretation of the data will require that OSHA exposure limits be amended to
account for the longer work shift. Additionally, the exposure limits will have to take into account a 7-
day workweek, rather than the standard 5-day workweek. Adjustments to exposure limits will be
made on a case-by-case basis.
Short duration monitoring - Several chemical parameters have established exposure limits based
on 15 or 30-minute exposures. This will require that samples for some parameters be collected
during activities that have the greatest potential for exposure during a given work shift. In addition to
15 and 30-minute duration, some chemical parameters have established ceiling limits. Grab
samples may be required to be collected to document compliance wth ceiling exposure limits.
Frequency-
Due to the number of variables involved with assessing worker exposures specific to this project and
the number of site workers, the establishment of comprehensive exposure data for a statistically
significant percentage (25%) of the work force will be difficult, and can not feasibly be achieved in a
single shift. Initially, exposure monitoring efforts will be concentrated on activities most likely to
result in elevated exposures. These classifications include those work groups where employees
spend the majority of their work shift handling debris, or otherwise working in close proximity to
debris being handled.
4.7.2 Information Management And Dissemination
Air sample data, both perimeter and personnel exposure monitoring, will be summarized and
disseminated accordingly. Data may be entered into a data base, which will be updated daily, will be
56
NYC-WTC_000150313
OCR can misread numbers and units. Confirm readings against the page image before using them.