Staten Island Landfill Debris Disposal Operation Health and Safety Program

Emergency Stop Devices—

Unless the design, construction, and operation of a conveyor is clearly non-hazardous to personnel, emergency stop buttons, pull cords, limit switches, or similar emergency devices shall be provided at the following locations for remotely or automatically controlled conveyors or conveyors where operator stations are not manned of are beyond voice and visual contact from drive areas:

Loading arms. Transfer points. Other potentially hazardous locations on the conveyor path not guarded by location or guards. I All emergency stop devices shall be easily identifiable and readily accessible. Emergency stop I I devices shall act directly on the control of the conveyor concerned and shall not depend on the stopping of any other equipment. Emergency stop devices shall be installed so that they cannot be overridden from other locations. I I Conveyor controls shall be arranged so that in case of an emergency stop, manual reset or restart is required at the location vUiere the emergency stop was initiated to resume conveyor operations. Control stations shall be arranged and located so that the operation of the equipment is visible from them. Controls shall be clearly marked or labeled to indicate the tinction controlled.

Portable Conveyors- The raising and lowering mechanism for the boom of a portable conveyor shall be provided with a safety device, which will hold boom at any rated angle of inclination.

Portable conveyors shall be stable so that the conveyor will not topple when used with the manufacturer's rating and in a manner in vhich it was intended or when being moved.

40

NYC-WTC_000150297

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000150297Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000150335 · Box DEP Box 11

Review draft of an environmental health and safety plan for debris operations at Staten Island Landfill.

Cited alongside this record in an Ask answer

Compare copies and versions →