NYC 9/11 Public Portal Document
?•- To: Building Owners
.
From: R. Radhakpshnan, P.E.
i
Department of Date: September 14,2001
Environmental
7] Subject: Clean-up of Asbestos-containing Material
59-17 Junction Boulevard
Corona, New York
11368-5107 ................ /
Building owners or their representatives instituting clean-up activities of areas
affected by the World Trade Center attack should follow these procedures:
Joel A. Miele Sr., P.E. _ 1. Minimal dust accumulations (light coating) can be cleaned using wet
Commissioner t. ,
methods and/or vacuums equipped with HEPA filters.
.. Robert C.Avaltroni
, Deputy Commissioner 2. HVAC-system filters should be replaced prior to re-occupancy.
Environmental Compliance 3. Accumulations of dust that include pieces of debris must be sampled by a
NYC- DEP certified investigator or NYS- DOL inspector to determine whether
the material is asbestos-containing material (ACM) or it may be assumed to be
ACM. Wipe sampling and/or micro-vacuum sampling are not recognized
■■■■■■ - . "
methods for asbestos sampling and should not be used. Bulk sample analysis
(PLM) must be performed by laboratories with ELAP accreditation.
4. Only individuals certified by the NYC-DEP as asbestos handlers can handle
dust and debris accumulations identified to be ACM or asbestos-contaminated
objects. ACM is any material containing more that one percent asbestos. All
work shall be performed in accordance with Title 15, Chapter 1 of the Rules of
the City of New York.
;; i i‘ i'i
5. Emergency telephone notification must be provided to the Department. The
telephone notification must include the name affiliation, and telephone number
of the caller; the exact location including street address, floor, and surface types
to be cleaned; the name, address, and telephone number of the NYS DOL
licensed asbestos contractor handling the material^ and the starting date. The
Asbestos and Lead, Control Program (ALCP) may be reached via (718) DEP-
HELP (24 hrs/7days).
6. A scope-of-work including the information outlined in number 3 above and
the procedures to be employed should be faxed to the ALCP at fax number
(718) 595-3744 or (718) 595-3648. The Department will review plans, provide
assistance, and offer recommendations. Our staff will be available to answer
your questions from 8:00 a.m. to 8:00 p.m. seven days per week. A field office
has been set up to expedite on-site assistance if necessary.
■ • . hV
7. Remote showering units shall be acceptable. The area where the installation
is proposed shall be pre-cleaned using wet wiping and/or HEPA vacuuming
procedures. The location of the unit shall be specified in the scope of work
- - ■
NYC-WTC_000150133
OCR can misread numbers and units. Confirm readings against the page image before using them.