NYC 9/11 Public Portal Document
furniture will be vacuumed using a stiff brush attachment.
f. Carpets will cleaned with a water extraction cleaner equipped with a motorized
agitator brush. Water extraction cleaning will not be conducted if it is determined
that it would cause damage to the carpet.
g- Paperwork and books will be HEPA vacuumed.
h. Electrical outlets will be vacuumed.
i. Window air conditioners will be vacuumed then removed fi'om their position and
vacuumed internally. Filters will be HEPA vacuumed and reinstalled. Air
conditioners will be reinstalled after cleaning.
j- Intake/discharge registers of HVAC systems (if present) will be removed/cleaned.
The first foot of duct work will also be vacuumed, then the register will be
reinstalled and covered with plastic.
k. Appliances such as refrigerators and stoves will be cleaned and moved. The floor
footprint of the appliances will be cleaned and the appliance will be reinstalled in
its original position.
1. Refiigerator cooling tubes will be brushed and vacuumed.
m. Stove exhaust fan filters will be cleaned.
n. The first foot of all exhaust duct work (including stove, dryer and bathroom vents)
will be vacuumed. Exhaust fans will be vacuumed and wiped.
o. Closet floors will be vacuumed.
P- Solid objects (electrical equipment, exercise equipment, etc.) will be wet wiped,
moved to allow cleaning of the underlying surface and will be returned to their
original location.
q- Dishwasher toe plates will be removed and the floor beneath the appliance will be
cleaned.
r. Baseboard heaters will be cleaned. Protective covers on finned radiant heaters and
baseboard heaters will be removed to expose heat elements. Fins are to be
brushed and vacuumed to remove dust.
s. All cleaning equipment will be vacuumed and/or wet wiped for use on the
residence.
Note that cleaning clothing and accessories (handbags, shoes, etc.) is the responsibility of the
resident. The Cleaning Contractor will not open and/or clean inside drawers, cabinets,
breakfronts, and similar enclosed storage or display pieces, however, the exterior of these pieces
will be cleaned.
The Project Monitor will oversee cleaning operations, and EPA staff will also visit residences to
oversee work. When cleaning is completed, the Project Monitor will do a visual inspection. If
dust is observed, the residence will be re-cleaned as necessary. Once the visual inspection finds
the residence to be dust free, final air sampling will be authorized.
This final testing phase will take approximately eight hours and must be completed within one
day (24 hours) of the completion of cleanup work. Residents have a choice between two forms
-3-
NYC-WTC_000149311
OCR can misread numbers and units. Confirm readings against the page image before using them.