NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/DEP Box 08/INTERIM FINAL April 2003
Document / 161 pages

EPA interim final report on WTC background study, April 2003

Machine-extracted title · confidence 100%

Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.

NYC-WTC_000145869–000146029

Folder label: “INTERIM FINAL April 2003”

Page image
Scanned page image, NYC-WTC_000145926
OCR text

OCR status: ok · source: pdftotext

z z o o i 1^ co

■D o c o CT o o' cn "0 CD o ro 03 o> Table 4-3 O o o c 3 Quality Control Wipe Spike Sample Results For Lead CD 3

Spike Sample True Value Percent QC Limit % Sample Identification Number Spike Added (g) (ug/wipe) +- 2% Results^ Recovery Recovery (ugZwipe) 13-BG-Common Area-Wipe Ceiling 1-L 0.0919 413 361 87% 80-120% 10-BG-Common Area-Wipe Ceiling 1-L 0.1018 457 397 87% 80-120% 11-BG-Common Area-Wipe Ceiling 1-L 0.0997 448 405 90% 80-120% 14-BG-Common Area-Wipe Ceiling 1-L 0.1063 477 414 87% 80-120% 9-BG-Common Area-Wipe Ceiling 1-L 0.1031 463 404 87% 80-120% 4-BG-Wipe Ceiling 1-L_____________ 0.0572 257 219 85% 80-120% 2-BG-Common Area-Wipe Ceiling 1-L 0.0530 238 189 79% 80-120% 8-BG-Wipe Ceiling 1-L_____________ 0.0956 429 432 101% 80-120% 3-BG-Wipe Ceiling 1-L_____________ 0.0602 270 209 78% 80-120% 5-BG-Wipe Ceiling 1-L_____________ 0.0504 226 205 91% 80-120% 1-BG-Common Area-Wipe Ceiling 1-L 0.0540 242 202 83% 80-120% 6-BG-Wipe Ceiling 1-L_____________ 0.0708 318 289 91% 80-120% 7-BG-Common Area-Wipe Ceiling 1-L 0.0681 306 294 96% 80-120% 12-BG-Common Area-Wipe Ceiling 1-L 0.0982 441 ND^ 80-120%

1 Result of the spike sample sent indistinguishably to the lab with field samples. 2 It is believed this sample was inadvertently switched at the laboratory with a counter wipe sample. The laboratory could not confirm this result, although the result of the counter wipe was 383 ug/ft^' where as the ceiling wipe sample was not detected.

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000145926Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Cited alongside this record in an Ask answer

NYC-WTC_000153247 · Box DEP Box 26

Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.