The recommended values were determined using two priorities:

as first priority, a combined data set, using both the residential and common areas and all samples from a specific media (e.g., settled dust) to achieve a larger sample size, was used unless the data from the separate areas were determined not to be similar’, in which case the second priority was used;

the second priority used the data set for the residential areas for all samples from a specific media, as the residential data sets had the second largest sample size and this data set would reflect the background concentration within a residential apartment.

6.2 Results and Development of Background Concentrations The following sections present a summary of the analytical results, the background values calculated, and a discussion that addresses the strengths and weaknesses for the asbestos, MMVF, lead, dioxin and PAH data sets, as well as the corresponding background value that was derived for each analyte, matrix, type of space, and type of surface. The statistical results and calculated UCLs are reported in Tables 6-1 through 6-3.

6.2.1 Asbestos* Bulk Dust - There were three bulk dust samples collected and analyzed for asbestos. All three samples were collected from the residential spaces. The results for the three samples were below the detection limit of 1%. Due to the small sample size and the results all being below the detection limit, the UCL for asbestos in bulk dust could not be calculated. The data suggest that background asbestos concentrations in bulk dust are less than 1%, however, the confidence in this statement is limited due to the small sample size.

Air - There were sixty-two air samples collected, forty-eight in residential spaces and fourteen in common spaces. Each of the samples were analyzed using Phase Contrast Microscopy (PCM), Transmission Electron Microscopy (TEM) AHERA, and TEM Phase Contrast Microscopy equivalents (PCMe) methods.

’The frequency of detection, range of detection, mean and calculated UCL for the residential and common area data sets were qualitatively compared to determine if they were similar. If any of the parameters were identified as not being similar, the second priority was used.

’For this study, the term structure and fiber are used interchangeably, although there are mineralogical nuances and counting rules that make these two terms technically different. In general, the analyses that were completed represent fibers, however for ease of comparison to the AHERA asbestos standard in a sister study, the term structure was adopted for all asbestos TEM analyses.

WORLD TRADE CENTER BACKGROUND STUDY 22

NYC-WTC_000145897

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000145897Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000132498 · Box DEP Box 54

A DEP report describing ambient outdoor air monitoring for asbestos in Lower Manhattan following the World Trade Center disaster.

Cited alongside this record in an Ask answer

NYC-WTC_000132628 · Box DEP Box 54

A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.

Cited alongside this record in an Ask answer

NYC-WTC_000142802 · Box DEP Box 06

Document defining indoor air quality terms such as acid aerosols and action levels for radon remediation.

Cited alongside this record in an Ask answer

Compare copies and versions →