At times during the project, the laboratory chose to perform analyses on samples that were neither
requested by EPA nor specified on the Chain of Custody. This was most evident in the case of
wipe samples that were collected for total dust. The QAPP required the collection of one pre
cleaning and one post-cleaning sample for total dust from each unit. These samples (wipes) also
served as the samples used for the analysis of crystaUine silica (alpha-quartz, cristobalite,
tridymite, calcite and gypsum). The crystaUine siUca sample was also collected pre-cleaning and
post-cleaning; however, it was collected from three locations in the unit. Upon submitting the
samples to the laboratory, specific direction was provided to the lab regarding which samples
were to be analyzed for total dust. The laboratory however, chose to prepare all three samples for
the total dust analysis rather than prepare the samples specified on the chain of custody.
A mercury vapor investigation was conducted as part of the study. The mercury vapor
investigation was conducted using a Lumex® analyzer’* that revealed a mean mercury vapor
concentration of 53.6 ng/m’ (range 3-210 ng/m^), demonstrating that air samples within the
building tested below EPA's Reference Concentration of 300 ng/m^. A statistical evaluation of
the results of the mercury vapor investigation is presented in Attachment K, Summary ofMercury
Vapor Results using the Lumex® Vapor Analyzer.
(Note: The following section does not include data and discussion ofwipe sampling resultsfor
alpha-quartz, calcite, gypsum, cristobalite, tridymite and total dust. The analytical resultsfor
these parameters were uncertain thereby rendering these data urmsable.)
Discussion ofAnalytical Results by Building Area
Unit 2A - This unit is located on the second floor. It is a 1,335 sq. ft. loft with one bedroom
facing Cedar Street. The unit has hardwood floors. The unit presented minimal dust
accumulation in the dwelling with the exception of the baseboard-heating units. The windows
were not blown in. AU personal items were disposed except for a couch and chairs.
Cleaning Method - The unit was cleaned using Test IB: use of a Ridgid® shop vacuum and
Hoover® upright vacuum for vacuuming the floors and other surfaces. Neither vacuum was
equipped with a HEPA filter. An AFD was used during the cleaning process. In addition, all
horizontal surfaces were wet wiped. This cleaning method was used for each cleaning event.
Cleaning Results - The unit met the primary clearance criteria listed in Table 1.0 for each
compound after being cleaned twice.
Asbestos
Before Cleaning Samples - Pre-cleaning micro vacuum and wipe samples were collected
for asbestos. These samples indicate that asbestos was present in the unit prior to
cleaning. Three of the four micro vacuum samples detected chrysotile. AU five wipe
samples detected chrysotile, although two of the samples were below the detection limit.
'^The instrument has a detection limit of 2 ng/m’.