POST CLEANING CONSUMER CHECKLIST YES NO

General Did the service provider obtain access to and clean the entire heating and cooling system, including duct work and all components (drain pans, humidifiers, coils, and fans)? Has the service provider adequately demonstrated that duct work and plenums are clean? (Plenum is a space in which supply or return air is mixed or moves; can be duct; joist space, attic and crawl spaces, or wall cavity.)

Heating Is the heat exchanger surface visibly clean?

Cooling Are both sides of the cooling coil visibly clean? Components If you point a flashlight into the cooling coil, does light shine through the other side? It should if the coil is clean. Are the coil fins straight and evenly spaced (as opposed to being bent over and smashed together)?

Is the coil drain pan completely clean and draining properly?

Blower Are the blower blades clean and free of oil and debris? Is the blower compartment free of visible dust and debris? Plenums Is the return air plenum free of visible dust and debris? Do filters fit properly and are they the proper efficiency as recommended by HVAC system manufacturer? Is the supply air plenum (directly downstream of the air handling unit) free of moisture stains and contaminants? Are interior ductwork surfaces free of visible debris? (Select several Metal Ducts sites at random in both the return and supply sides of the system.)

Fiberglass Is all fiberglass material in good condition (i.e., free of tears and abrasions; well adhered to underlying materials)?

Access Are newly installed access doors in sheet metal ducts attached with Doors more than just duct tape (e.g., screws, rivets, mastic)? With the system running, is air leakage through access doors or covers very slight or non-existent? Air Vents Have all registers, grilles, and diffusers been firmly reattached to the walls, floors, and/or ceilings? Are the registers, grilles, and diffusers visibly clean?

System Does the system function properly in both the heating and cooling Operation modes after cleaning?

10

NYC-WTC_000142830

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000142830Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →