hiuuui AIT i^uaiiLj - Glossary oi terms Page 7 of 8
exhaust grilles before entering the breathing zone (area of a room where people are).
To avoid short-circuiting, the supply air must be delivered at a temperature and
velocity that results in mixing throughout the space.
SICK BUILDING SYNDROME (SBS): Term that refers to a set of symptoms that
affect some number of building occupants during the time they spend in the building
and diminish or go away during periods when they leave the building. Cannot be
traced to specific pollutants or sources within the building. (Contrast with "Building
related illness").
SOIL GAS: The gas present in soil which may contain radon.
SOIL-GAS-RETARDER: A continuous membrane or other comparable material used
to retard the flow of soil gases into a building.
SOURCES: Sources of indoor air pollutants. Indoor air pollutants can originate within
the building or be drawn in from outdoors. Common sources include people, room
furnishings such as carpeting, photocopiers, art supplies, etc.
STACK EFFECT: The overall upward movement of air inside a building that results
from heated air rising and escaping through openings in the building super structure,
thus causing an indoor pressure level lower than that in the soil gas beneath or
surrounding the building foundation.
STATIC PRESSURE: Condition that exists when an equal amount of air is supplied to
and exhausted from a space. At static pressure, equilibrium has been reached.
STERILIZER: One of three groups of anti-microbials registered by EPA for public
health uses. EPA considers an anti-microbial to be a sterilizer when it destroys or
eliminates all forms of bacteria, fungi, viruses, and their spores. Because spores are
considered the most difficult form of a microorganism to destroy, EPA considers the
term sporicide to be synonymous with "sterilizer."
SUB-SLAB DEPRESSURIZATION SYSTEM (ACTIVE): A system designed to
achieve lower sub-slab air pressure relative to indoor air pressure by use of a fan-
powered vent drawing air from beneath the slab.
SUB-SLAB DEPRESSURIZATION SYSTEM (PASSIVE): A system designed to
achieve lower sub-slab air pressure relative to indoor air pressure by use of a vent
pipe routed through the conditioned space of a building and connecting the sub-slab
area with outdoor air, thereby relying solely on the convective flow of air upward in the
vent to draw air from beneath the slab.
SUB-MEMBRANE DEPRESSURIZATION SYSTEM: A system designed to achieve
lower sub-membrane air pressure relative to crawlspace air pressure by use of a fan-
powered vent drawing air from under the soil-gas-retarder membrane.
TRACER GASES: Compounds, such as sulfur hexaflouride, which are used to identify
suspected pollutant pathways and to quantify ventilation rates. Trace gases may be
detected qualitatively by their odor or quantitatively by air monitoring equipment.
TLVs - Threshold Limit Values (guidelines recommended by the American Conference
of Governmental Industrial Hygienists).
TVOCs. Total volatile organic compounds. See "Volatile Organic Compounds (VOCs)"
UNIT VENTILATOR: A fan-coil unit package device for applications in which the use
http://www.epa.gov/iaq/glossary.htnil 4/8/02