Machine-extracted title · confidence 72%

Inspection checklist for HVAC system components including mechanical room conditions, outside air intake accessibility, WTC dust presence, and component condition documentation.

NYC-WTC_000140021

Folder label: “EPA HVAC ACTION PLAN (Indoor Clean up)

Page image
Scanned page image, NYC-WTC_000140021
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.3 Mechanical Make-up Air System Visual Inspection Form Page 1 of2

Mechanical Make-up Air System Identification: Location: Area Served:

Associated mechanical room: clean Y N dry Ystored chemicals/refuse N Y N Surface Component System Components (if component not present, not foimd or inaccessible please Dust/ WTC not indicate) Debris Dust present Present? Present? not found

inaccessible Outside air intake: Location:

Accessible for inspection? Y N (explain):

______________ louvers, grates and/or screens________________________________ ______________ outside air duct____________________________________________ ______________ outside air damper(s)_______________________________________ Make-up air handling unit:_______________________________________________ outside air mixing chamber ______________ filter rack(s)______________________________________________ ______________ filter media_______________________________________________ blower assembly incl. blower wheel, blower housing, air vanes, in-line _______ noise attenuators ;_________________________________________________ ______________ blower housing acoustical lining______________________________ ______________ pre-heat coils_____________________________________________ ______________ heating coils______________________________________________ ______________ cooling coils______________________________________________ ______________ re-heat coils_________________________ _____________________ ______________ condensate drain pan_______________________________________ ______________ supply air plenum__________________________________________ supply air plemun damper(s) vibration collars Make-up air distribution: Make-up air ducts Est.Total In ft No. locations inspected Specify type (circle): metal fibrous glass lined metal masonry fibrous glass board flex-duct wood

Accessible in-line fire dampers Est. total qty No. locations inspected Accessible turning vanes Est. total qty No. locations inspected In-line reheat/cooling coils Est. total qty No. locations inspected Supply air diffusers Est. total qty No. locations inspected Other (specify):

Other Information: Filter loading (light, moderate, heavy): Abraded/delaminated acoustical lining Filter bypass (describe)

2.3 Mechanical Make-up Air System Visual Inspection Form Page 2 of2

NYC-WTC_000140021

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000140021Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →