generally those less than six months old. Pulmonary hemosiderosis is an
uncommon condition that results from bleeding in the lungs. The cause of this
condition is unknown, but may result from a combination of environmental
contaminants and conditions (e.g., smoking, fungal contaminants and other
bioaerosols, and water-damaged homes), and currently its association with SC is
unproven.
The focus of this guidance document addresses mold contamination of building
components (walls, ventilation systems, support beams, etc.) that are chronically
moist or water damaged. Occupants should address common household sources
of mold, such as mold found in bathroom tubs or between tiles with household
cleaners. Moldy food (e.g., breads, fruits, etc.) should be discarded.
Building materials supporting fungal growth must be remediated as rapidly as
possible in order to ensure a healthy environment. Repair of the defects that led
to water accumulation (or elevated humidity) should be conducted in conjunction
with or prior to fungal remediation. Specific methods of assessing and
remediating fungal contamination should be based on the extent of visible
contamination and underlying damage. The simplest and most expedient
remediation that is reasonable, and properly and safely removes fungal
contamination, should be used. Remediation and assessment methods are
described in this document.
The use of respiratory protection, gloves, and eye protection is recommended.
Extensive contamination, particularly if heating, ventilating, air conditioning
(HVAC) systems or large occupied spaces are involved, should be assessed by
an experienced health and safety professional and remediated by personnel with
training and experience handling environmentally contaminated materials. Lesser
areas of contamination can usually be assessed and remediated by building
maintenance personnel. In order to prevent contamination from recurring,
underlying defects causing moisture buildup and water damage must be
addressed. Effective communication with building occupants is an essential
component of all remedial efforts.