HVAC inspection report, 295 Greenwich Street, Feb 2003

Machine-extracted title · confidence 95%

An HVAC inspection report from Cole Consulting Corporation dated February 13, 2003, recommending cleaning of units at 295 Greenwich Street due to WTC dust.

NYC-WTC_000134597–000134636

Folder label: “295 GREENWICH 1066187, 137/7502

Page image
Scanned page image, NYC-WTC_000134617
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.2 ; Mechanical Exhaust System Visual Ins ection Mechanical Exhaust S •stem Identification: Form Location: n ~v I of iC-C~c~ r JArea Served: Associated mechanical room: clean y ' do ?~ stored chernicaisrrefuse :y System Components Surface I:NOTE: if component not present (\P), Component not found (\F) or nor indicate in last column] inaccessible (I) please Debris Dust present Present? Present? not found Exhaust air outlet: Loc lion:

Accessible for inspection? Y LN, —~ (explain):

lou%'ers, crates and'or screens outside air duct outside air dam er(s) Exhaust fan unit: blower assembly incl. blower wheel, attenuators housing. air vanes, in line noise blower housing acoustical lining N %•ibration collars Exhaust air distribution: Exhaust air ducts Est total In ft inspected_ --- — ho. locations Specify type (circle): J rousela s lined metal \ n ry fibrous el s board duct Accessible in-line fire dam ers Est. total tv t Accessible turnins vanes 1\o. locations ins ected a Est total otti No. locations inspected Exhaust aiz rilles Est. total h Other (specify): To. locations Inspected

Other Information:

C.er<er., Sfarl~r:c2 /: A: - .-•• • ....,u+;r for cie:.ning based oil finding of 1~~TC dust):

tv w -`C Qus r Fou..~lJ

7`Ii.E1': N == not A-esen uunu: i = i accessible; U

NYC-WTC 000134617

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000134617Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000133682 · Box DEP Box 55

Blank form for evaluating ventilation systems including building contact details and system types at the World Trade Center site.

Similar indexed content

NYC-WTC_000133722 · Box DEP Box 55

Memo recommending cleaning of specific roof equipment at 295 Greenwich Street after WTC dust was found during inspection.

Similar indexed content

Compare copies and versions →