HVAC inspection report, 295 Greenwich Street, Feb 2003

Machine-extracted title · confidence 95%

An HVAC inspection report from Cole Consulting Corporation dated February 13, 2003, recommending cleaning of units at 295 Greenwich Street due to WTC dust.

NYC-WTC_000134597–000134636

Folder label: “295 GREENWICH 1066187, 137/7502”

Page image
Scanned page image, NYC-WTC_000134608
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.2 Mechanical Exhaust S~'Stem NrlSuaI Inspection Form Mechanical Exhaust System ldentificatian: Location: I of Area Served: Associated mechanical room: clean T dr • Y N stored chemicals.!refuse System Components [NOTE: if component not present Surface (1\P), not found (\F) or Dust! Component indicate in last column) inaccessible (1) please 117C not Debris Dust Present? present Present? not found Exhaust air outlet: Lo: Lion:

Accessible for inspection? Y 1,* (exphin): louers, crates and!or screens outside air duct Y' I ',) outside air damper(s) Exhaust fan unit: blower assembly incl. blower o Wheel, housing. air vanes, in-line attenuators noise blower housing acoustical lining - .• -- Al vibration collar; T Exhaust air distribution: Exhaust air ducts Est total In ft J t} inspec led,_ No. locations Specify type (circle): eta fibrous elzss lined met pitaso. ry rbrous ex-duct wooer Accessible in-line fire dampers Est. total lc assob ard Y j ry gr%, No. locations ins ected Accessible tumint vanes Est total qty 0 1-':}:' ist ai. grilles No. locations inspected Est. total n 1\o. locations inspected Q Other (specify):

Ot1l:r• Irifcr•r:::iti.~n:

• ~. wuur.tai:i:i0n s u. r cleaning based oil finding of VTC dust):

J • tA1 i AL to a S r V u 1./ t . t

l\P =not present; >\F =not found• I = inaccessible. Lr a unknoicn

NYC-WTC 000134608

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000134608Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000133682 · Box DEP Box 55

Blank form for evaluating ventilation systems including building contact details and system types at the World Trade Center site.

Similar indexed content

NYC-WTC_000133722 · Box DEP Box 55

Memo recommending cleaning of specific roof equipment at 295 Greenwich Street after WTC dust was found during inspection.

Similar indexed content

Compare copies and versions →