HVAC inspection report, 275 Greenwich Street, Feb 2003

Machine-extracted title · confidence 95%

An HVAC inspection report from Cole Consulting Corporation dated February 13, 2003, recommending cleaning of units at 275 Greenwich Street due to WTC dust.

NYC-WTC_000134538–000134590

Folder label: “275 GREENWICH 1081076, 132/7501

Page image
Scanned page image, NYC-WTC_000134582
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.2 Mechanical Exhaust System Visual Inspection Form Mechanical Exhaust System Identification: . -- __. _ . .. Page I of I Location: ntG.4h~ Area Served: Associated mechanical rom o . 1can 1 N d Y N stored chemicals!refuse Y N System Components Surface Component (NOTE: if component not present (NP), not found (NF) Dust' UTC not or inaccessible (I) please Debris Dust indicate in last column} present Present? Present? not found

Exhaust air outlet: Location:

Accessible for inspection? Y V N (explain):

lout'ers, grates and'or screens • outside air duct outside air damper(s) Exhaust fan unit: blower assembly incl. blower wheel, housing, air vanes, in-line noise attenuators blower housing acoustical lining vibration collars Exhaust air distribution: Exhaust air ducts Est total In ft I Z~ No. locations inspected ibrovs •' y 1Y Specify type (circle): meta p ¢lass lined metal masonry fibrous glass board flex-duct ~~•ood - Accessible in-line fire dampers Est. total qtv No. Iocations inspected I D Accessible turning vanes Est. total qty No locations inspected Exhaust air grilles Est. total qty No locations inspected Other (specify): 0

Other Information:

General impression (indicate recommendations for cleaning based on finding of RTC dust):

✓t f t t`"cJ.i „J +, , ,V Sr$ j n! ( i , ~-+.0 U ~?:'7,~..✓

KEY: NP = NF= not found; 1=1 _

NYC-WTC 000134582

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000134582Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000133722 · Box DEP Box 55

Memo recommending cleaning of specific roof equipment at 295 Greenwich Street after WTC dust was found during inspection.

Similar indexed content

Compare copies and versions →