VENTILATION SYSTEM EVALUATION FORM Part 1 O f;annral infnrmatinn Date of Evaluation: 9-24-02.2 Report #2 I Building contact name and phone: Walter Gryzybonska/ (212)269-3003 Evaluation Team (list name and affiliation): Claude, Linton, Joy K. Kurin (Environmental Professional) Cole Consulting Inc. (HVAC/Electrical Professional) D.J.H.Mechanical Associates, Ltd. (Sheet Metal Professional) Building Address: 45 Wall Street Type of Facility (check all that apply): New York, NY 10005 ❑ Residential Multi-use ❑ Other (describe) Number of residential units: NIC Number of floors: 29 + 2(B) HVAC System Types (check all that apply) ❑ Unit ventilator (single residence unit) ❑ Wall/window AC unit (single residence unit) ❑ Fan coil unit (single residence unit) ® Central ventilation system ❑ Heat pump unit (single residence unit) ❑ Passive shaft/duct ❑ Other (describe) H. V. Location of outside air intake: William Street and Exchange place Outside air intake accessible for inspection: yes (explain)
2.0 General Description Of HVAC System
No. of Air Intakes: - Three (3) Location of Air Intakes: 1 small fresh air intake at exchange Place and two in William Street
Floor Served: - Sub cellar 2 (boiler room) Whether Intakes at Street Level:- yes No. of Rooftop Blower/Mushroom Vents: 15 Individual Heating / AC unit Present or not: - NA
General Description: - Two exhaust pumps in the basement, which serve 1st to 17th24th floor for kitchen and bathroom air out. Two Additional small exhaust pumps located on 18`h floor. They serve 18`h — floors for bathrooms and kitchens air out. In addition, 15 mushroom fans on rooftop to serve 25`h — 30`h floors for kitchens and bathrooms air out. Enclosed please find pictures taken of the passive shaft/duct duct shaft and mushroom fans, which showed no signs of WTC dust debris.
2.2 Fan coil/ heat pump units in common spaces Ventilation System Identification: McQuay LHD114DH Serial # 37B00581-04 H.V.1 Location: Boiler Room Sub cellar Access adequate for inspection of components: Yes A I B C D Dust/Dirt/Debris E Suspect WTC-Related Dust System Component Color Light Heavy Present? Estimate % of total dust Substrate Material W- White (<1/16 inch (z 1/16 inch (YIN) loading (sheet metal wrapped) B - Brown depth) depth (sheet metal lined) G - Grey System Components (fiberglass) BG-Black gray (flexible connector) (double walled) Return air grille Sheet metal B& G z 1/16 inch YES 18%
Fresh Air Intake Grille Sheet Metal B, W, & G z 1/16 Inch Return air plenum Sheet metal White Dust <1/l6 inch YES 18% on To Filter rack Sheet Metal Lined G 2 1/16 inch YES 18% Filter media Fiberglass Disposable G z 1/16 inch 20x25x2 Blower assembly Sheet metal G < 1/16 inch
NYC-WTC 000133627
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000132808
Inspection form for HVAC units at a NYC address dated November 6, 2002.
4 shared non-person entities · 1 shared topics · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132702
Inspection report documenting HVAC units at 176 Broadway identified as containing World Trade Center debris.
4 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099514
Inspection report listing rooftop units at 75-79-81 Nassau Street where possible World Trade Center debris was identified in November 2002.
4 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132813
Inspection report detailing air duct cleaning status for HVAC units at 75-79 [name] following WTC debris cleanup.
4 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132823
Inspection report listing fan models and conditions at a NYC address in November 2002.
4 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115031
Inspection report for HVAC ducts at 261 Water Street checking for possible World Trade Center debris contamination.
4 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132828
Inspection report listing fan models and conditions at a NYC address in November 2002.
4 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000118876
A form for recording WTC debris inspection results at 80 Beekman Street, including facade and air monitoring data.
4 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132707
Inspection report documenting HVAC units at 257 Water Street identified as containing World Trade Center debris.
4 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132818
Inspection report listing fan models and conditions at a NYC address in November 2002.
4 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117662
Header of a fax dated January 5, 2000, containing illegible text and references to an inspection report.
4 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132697
A laboratory analysis report from New York Lab detailing fiber counts for air samples collected at 115 Broadway.
4 shared non-person entities · 1 shared topics · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140302
Form for recording building contact details, facility type, and HVAC system components during pre-cleaning evaluations.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163408
Second addendum to monitoring scope including HVAC system checklist and inspection procedures.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140477
Form for recording facility details and HVAC system types during World Trade Center dust evaluation inspections.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
Similarity score 0.969 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000132808
Inspection form for HVAC units at a NYC address dated November 6, 2002.
Similar indexed content
Inspection report documenting HVAC units at 176 Broadway identified as containing World Trade Center debris.
Similar indexed content
NYC-WTC_000099514
Inspection report listing rooftop units at 75-79-81 Nassau Street where possible World Trade Center debris was identified in November 2002.
Similar indexed content
NYC-WTC_000132813
Inspection report detailing air duct cleaning status for HVAC units at 75-79 [name] following WTC debris cleanup.
Similar indexed content
NYC-WTC_000132823
Inspection report listing fan models and conditions at a NYC address in November 2002.
Similar indexed content