NYC-WTC_000132808
Inspection form for HVAC units at a NYC address dated November 6, 2002.
4 shared non-person entities · 1 shared topics · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗Memo recommending cleaning of HVAC components at 45 Wall Street following a visual inspection related to World Trade Center reports.
NYC-WTC_000133531–000133628
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
VENTILATION SYSTEM EVALUATION FORM Part 1.0 General Information Date of Evaluation: 9-30-02 Report #1 Building contact name and phone: Walter Grzybonska/ (212) 269-3003 4th Floor Hallway Evaluation Team (list name and affiliation): Claude Linton / Joy K. Kurin Environmental Professional: Cole Consulting Inc. HVAC Contractor: DJH MECHANICAL ASSOCIATES LTD. Sheet Metal Professional: Building Address: 45 Wall Street, New Type of Facility (check all that apply): York, NY 10005 ❑ Residential Building Age: 45 Years ® Multi-use Distance from Ground Zero: Half Mile ❑ Other (describe) Direction from Ground Zero: South East Number of residential units: NIC Number of floors: 29 + 2(b) HVAC System Types (check all that apply) ❑ Unit ventilator (single residence unit) ❑ Wall/window AC unit (single residence unit) LI Fan coil unit (single residence unit) LI Central ventilation system ® Heat pump unit (single residence unit) LI Passive shaft/duct This pump supplying heat and cool to the room. HVAC Shut Down: System Didn't Shutdown Frequency of filter change-outs: Every Two months in Commercial Place I Impacted by WTC dust: No Location: 4'h Floor Hallway System Cleaned: No. Outside air intake accessible Yes x No (explain) There is no fresh intakes.
2.0 General Description Of HVAC System
No. Of Air Intakes: - 0 (No Fresh air intakes) Location of Air Intakes: - N/A
Floor Served: - N/A Whether Intakes at Street Level: -N/A No. Of Rooftop Blower/Mushroom Vents: 15 General Description: -N/A Individual Heating / AC unit Present or not: - YES
General Description: Two exhaust pumps in the basement, which serve 15` to 17th floor for kitchen and bathroom air out. Two additional small exhaust pumps located on 18th floor. They serve 18"' — 24"' floors for bathrooms and kitchens air out. 11 In addition, 15 mushroom fans on rooftop to serve 25`h — 30 ' floors for kitchens and bathrooms air out. Enclosed please find pictures taken of the passive shaft/duct shaft and mushroom fans, which showed no signs of WTC dust debris.
3.0 Fan coil/ heat pump units in common spaces
Ventilation System Identification: Make: McQuay M#FCV036BMGR Serial No. 77AO4558-03 Location: 4`h Floor Closet Serve: - Serving heat and cool air toCoridor. Access adequate for inspection of components: Yes A B C D Suspect WTC-Related Dust Dust/Dirt/Debris System Component Color Light Heavy Present Estimate % of total Substrate Material W- White (< 1/16 (>_ 1/16 inch depth ? (Y/N) dust loading (sheet metal wrapped) B - Brown inch depth) G - Grey System Components (sheet metal lined) B - Black (fiberglass) (flexible connector) (double walled) Return air grille Sheet Metal B& G < 1/16 inch No -------
NYC-WTC 000133543
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000132808
Inspection form for HVAC units at a NYC address dated November 6, 2002.
4 shared non-person entities · 1 shared topics · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132702
Inspection report documenting HVAC units at 176 Broadway identified as containing World Trade Center debris.
4 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099514
Inspection report listing rooftop units at 75-79-81 Nassau Street where possible World Trade Center debris was identified in November 2002.
4 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132813
Inspection report detailing air duct cleaning status for HVAC units at 75-79 [name] following WTC debris cleanup.
4 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132823
Inspection report listing fan models and conditions at a NYC address in November 2002.
4 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115031
Inspection report for HVAC ducts at 261 Water Street checking for possible World Trade Center debris contamination.
4 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132828
Inspection report listing fan models and conditions at a NYC address in November 2002.
4 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000118876
A form for recording WTC debris inspection results at 80 Beekman Street, including facade and air monitoring data.
4 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132707
Inspection report documenting HVAC units at 257 Water Street identified as containing World Trade Center debris.
4 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132818
Inspection report listing fan models and conditions at a NYC address in November 2002.
4 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117662
Header of a fax dated January 5, 2000, containing illegible text and references to an inspection report.
4 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132697
A laboratory analysis report from New York Lab detailing fiber counts for air samples collected at 115 Broadway.
4 shared non-person entities · 1 shared topics · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140302
Form for recording building contact details, facility type, and HVAC system components during pre-cleaning evaluations.
Similarity score 0.965 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
Similarity score 0.965 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163408
Second addendum to monitoring scope including HVAC system checklist and inspection procedures.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140477
Form for recording facility details and HVAC system types during World Trade Center dust evaluation inspections.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000132808
Inspection form for HVAC units at a NYC address dated November 6, 2002.
Similar indexed content
Inspection report documenting HVAC units at 176 Broadway identified as containing World Trade Center debris.
Similar indexed content
NYC-WTC_000099514
Inspection report listing rooftop units at 75-79-81 Nassau Street where possible World Trade Center debris was identified in November 2002.
Similar indexed content
NYC-WTC_000132813
Inspection report detailing air duct cleaning status for HVAC units at 75-79 [name] following WTC debris cleanup.
Similar indexed content
NYC-WTC_000132823
Inspection report listing fan models and conditions at a NYC address in November 2002.
Similar indexed content