NYC 9/11 Public Portal Document
EMSL Analytical, Inc.
107 Haddon Ave., Westmont, NJ 08108
Phone: (886) 858.4800 Fax: (888) 858-4960 Email: asiegel(f4EMSL.com
Attn: CTSI-Consulting & Testing Services, Inc. Customer ID: CTSI50
622 Georges Rd. Customer PO:
North Brunswick, NJ 08902
Received: 10/24/01 6:45 PM
Fax: (732) 729-1803 Phone: 732-729-1800
EMSL Order. 040116582
Project: 115 BROADWAY/ENTIRE BLDG EMSL Project ID:
Analysis Date: 10/25/2001
Fiber Analysis of Air Samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94
LOB Fibers/ Fibers/
Sample Location Sample Date Volume Fibers Fields (fib/cc) mm2 cc Notes
13 19TH FL NORTH 10/24/2001 1800.00 12.0 100 0.001 15.29 0.003
SIDE
040116582-0013
14 18TH FL CAFE 10/24/2001 1800.00 <5.5 100 0.001 <7.0 <0.001
040116582-0014
15 17TH FL HALL EAST 10/24/2001 1800.00 12.0 100 0.001 15.29 0.003
SIDE
040116582-0015
16 16TH FL CENTER 10/24/2001 1800.00 <5.5 100 0.001 <7.0 <0.001
040118882-0016
17 15TH FL ELEV 10/24/2001 1800.00 13.0 100 0.001 16.56 0.004
LOBBY
040116582-0017
18 14TH FL N-E SIDE 10/24/2001 1800.00 7.5 100 0.001 9.55 0.002
040116582-0018
19 13TH FL HALL 10/24/2001 1800.00 13.0 100 0,001 16.56 0.004
CENTER
040116582-0019
20 12TH FL HALL 10/24/2001 Overloaded
WEST SIDE
040116582-0020
21 BLANK 10/24/2001 0.00 <5.5 100 <7.0 Field Blank
040116562-0021
22 BLANK 10/24/2001 0.00 <5.5 100 <7.0 Field Blank
040116582-0022
e-) 8
Dave Stanhope
Analyst Stephen Siegel, CIH
or other approved signatory
Umit of detection is 7 fibers/mm. The laboratory is not responsible for data reported in fiboralcc, which is dependent on voiwne collected by non-labors peraonnai, this report
relates only to the samples reported above. This report may not be reproduced, except in full, without written approval by EMSL
Analysis performed by EMSL Westmont (NY State FLAP #10872)
CM 2
t. -
NYC-WTC 000133157
OCR can misread numbers and units. Confirm readings against the page image before using them.