Attn: CTSI-Consulting & Testing Services, Inc. Customer ID: CTSI50
622 Georges Rd. Customer PO:
North Brunswick, NJ 08902
Received: 10/21/01 9:10 PM
Fax: (732) 729-1803 Phone: 732-729-1800
EMSL Order. 030106703
Project: 115 Broadway/Entire Bldg/AQ EMSL Project ID:
Analysis Date: 10/22/01
Fiber Analysis of Air Samples via NIOSH 7400, Revision 3, Issue 2, $/15194
LOD Fibers/ Fibers/
Sample Location SampleDate Volume Fibers Fields (fib/cc) mm= cc Notes
01 11th Fl-East/Offices 10/21/01 1800.00 <5.5 100 0.001 <7.0 <0.001
030106703.0001
02 10th Fl-West/Offices 10/21/01 2057.00 <5.5 100 0.001 <7.0 <0.001
030106703-0002
03 9th Fl-West/Offices 10/21/01 1800.00 <5.5 100 0.001 <7.0 <0.001
030106703.0003
04 8th Fl-West/Offices 10/21/01 2040.00 <5.5 100 0.001 <7.0 <0.001
030106703-0004
05 7th Fl-West/Offices 10/21/01 1920.00 <5.5 100 0.001 <7.0 <0.001
030106703-0005
06 6th Fl-West/Offices 10/21/01 1680.00 <5.5 100 0.002 <7.0 <0.002
030106703.0006
07 5th Fl-West/Offices 10/21/01 2178.00 <5.5 100 0.001 <7.0 <0.001
030106703-0007
08 4th Fl-West/Offices 10/21/01 2040.00 <5.5 100 0.001 <7.0 <0.001
030106703-0008
09 2nd Fl-East/HalMrey 10/21/01 1210.00 <5.5 100 . 0.002 <7.0 <0.002
030106703.0009
10 1st Fl-West/Elevator 10/21/01 1694.00 <5.5 100 0.002 <7.0 <0.002
lobby
030106703-0010
11 2st Fl-West/Offices 10/21/01 1560.00 <5.5 100 0.002 <7.0 <0.002
030106703.0011
12 20th Fl-East/Offices 10/21/01 1815.00 <5.5 100 0.001 <7.0 <0.001
030106703-0012
Charme/ Dozier
Analyst Laboratory Manager
or other approved signatory
Limit of detection is 7 flbersM m'. The laboratory Is not responsible for data reported in fibersfca, whkth Is dependent on volwte collected by non-legato y personnel. This rep
relates only to the samples reported above. This report may not be reproduced, except in full, without written approval by EMSL
Analysis performed by EMSL Manhattan (NY State FLAP #11508)