NYC 9/11 Public Portal Document
October 22, 2001
Mr. Kevin Hoey
Property Manager
CAPITAL PROPERTIES
111 Broadway
New York, NY 10006
RE: ENVIRONMENTAL SAMPLING SERVICES PERFORMED AT
111 BROADWAY, ENTIRE BUILDING, NEW YORK, NY
Dear Mr. Hoey:
On October 20`h, 2001, Consulting and Testing Services, Inc. (CTSI) has performed air quality
sampling from various floors from the above referenced building.
Air samples were collected as part of building air quality/dust control evaluation from all the
floors. All samples collected were transported to an independent certified laboratory, EMSL
Analytical, for analysis. Samples were analyzed utilizing Phase Contrast Microscopy (PCM)
Methodology (Fiber Analysis of Air Samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94).
•
Based on the attached certificate of analysis, the air quality samples collected on October 20`h,
2001, indicate fiber counts are within the Occupational Safety & Health Administration
(OSHA) Permissible Exposure Limit (PEL) of 0.1 f/cc (fibers per cubic centimeter). A total of
twenty two (22) air quality samples were collected.
Please feel free to call us with any questions or if you need further information.
Sincerely,
CONSULTING AND TESTING SERVICES, INC.
Frank Salami
President
'CC: David Parisier
Attach.
S
622 Georges Road, Suite 301
North Bruaswidr, N108902
Telz (212) 929-3151 or (732) 729-1800
ENVIRONMENTAL. SAPM&HEALTH PROFESSIONALS Fa= (732) 729-1803
NYC-WTC 000133025
OCR can misread numbers and units. Confirm readings against the page image before using them.