AIfltp,he. 111-115 Broadway,New York,New York

EXECUTIVE SUMMARY AKRF, Inc. (AKRF) was retained by Rosenman & Colin LLP to perform Indoor Air Monitoring within 111-115 Broadway in New York City. The project site consists of two (2) twenty-one story buildings 115 Broadway is located north of 111 Broadway, and Thames Street runs between the two buildings. The buildings are approximately 98 years old and are mirror images of each other. AKRF collected air samples for laboratory analysis at sixteen locations throughout the project site between November 26 and 30, 2001. The air samples were analyzed for the following constituents: Volatile Organic Compounds (VOCs); Polynuclear Aromatic Hydrocarbons (PAHs); metals (arsenic, beryllium, cadmium, chromium, cobalt, copper, iron, lead, nickel, manganese, silver, thallium and zinc); aldehydes; asbestos fibers; silica; respirable particulates; and dioxins. Temperature, Relative Humidity, Carbon Dioxide and Carbon Monoxide concentrations were measured throughout the buildings using a Metrosonics aq-5000 direct read meter. - Based upon the results of this indoor air quality investigation, AKRF presents the following findings: • Levels of polynuclear aromatic hydrocarbons (PAHs), metals, asbestos, respirable particulate, silica, and volatile organic compounds (VOCs) were all observed to be below regulatory and recommended guidelines. • Levels of formaldehyde were observed* to be well below OSHA regulatory requirements. Eight samples were observed to be above the NIOSH recommended exposure level. All other levels of aldehydes were observed to be below regulatory and recommended guidelines. • Levels of dioxins above the analytical detection level were identified within one sample. All other samples revealed no detectable levels of dioxins. No regulatory limit exists for occupational exposure to dioxins. NIOSH has recommended, absent other guidelines, that levels of dioxins be reduced to the lowest feasible concentration. • Relative humidity, carbon dioxide and carbon monoxide levels were all observed to be within established ASHRAE guidelines. Some temperature readings throughout both buildings were observed to be above the ASHRAE guidelines for wintertime conditions. Because the sampling was conducted within unoccupied spaces, temperature variations may be due to the building's systems settings. Based upon the conclusions of this indoor air quality investigation, no specific recommendations are presented at this time. However, because of the continuing concerns of people occupying the downtown area along with the continuing press coverage, Rosenman & Colin LLP may wish to consider additional indoor air quality monitoring. Should this monitoring be performed, AKRF suggests that this monitoring include temperature, relative humidity, carbon dioxide, carbon monoxide, respirable dust and asbestos sampling. In addition, mercury should be sampled for in both the dust and fume forms. To alleviate any possible concerns with formaldehyde, sampling in the affected spaces could be conducted with the ventilation system in operation, as it would be with full occupancy. Sampling

NYC-WTC 000132578

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000132578Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000132654 · Box DEP Box 54

A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.

Similar indexed content

NYC-WTC_000132628 · Box DEP Box 54

A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.

Similar indexed content

NYC-WTC_000132548 · Box DEP Box 54

Cover letter from Capital Properties submitting additional air quality monitoring results for Broadway buildings to DEP.

Similar indexed content

Compare copies and versions →