NYC-WTC_000131197
HBHREHEESEEH &SES&
er ike STO aee BHRHHRHHEHEEHEHHEHHRHHHAREHBRHEEHEEHEE EE
Client Name: Hillmann Environmental Company, Inc.
Table I
Summary of Transmission Electron Microscopy (TEM) Results for Asbestos (air)
Marriot; 85 West Street (Roy's Resturant)
Structure Structure
Air Area x Analytical Asbestos Structures Detected Density Concentration Type
SciLab Client Dilution Filtered Analyzed Sensitivity (Microns) (struc/sq. mm.) —_(struc/cc air) of
Sample # Sample # Factor (liters) (sq.mm.) (struc/ccair) 0.5-5.0 >5.0 Total >5.0 Total >5.0 Total Asbestos
oi** DC092801 1200
Ist Floor WAI 10' Of Elevator + Bath SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUALITATIVE SCAN/
02** DC092802 1200
Ist Floor Main Lobby /SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUALITATIVE SCAN/
o3** DCO92803 1200
Ist Floor WA 10° Of C/R Barrier Between Corridor And Airlock /SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUAL
04** DC092804 1200
Ist Floor Between Back Door + Airlock /SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUALITATIVE SCAN/
0s** DC092809 1200
Ist Floor W/I 10' Of Elevator + Bath SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUALITATIVE SCAN/
06 DC092810 1200 A 0.0032 0.0 0.0 0.0 <10 <10 <0.0032 <0.0032 NSD
Ist Floor Main Lobby
07 DC092812 1200 A 0.0032 0.0 0.0 0.0 <10 <10 <0.0032 <0.0032 NSD
Ist Floor Between Back Door + Airlock
08 DC092820 1200 A 0.0032 0.0 0.0 0.0 <10 <10 <0.0032 <0.0032 NSD
1st Flooor Between Back Door + Airlock
09 DC092821 1200 | 0.0032 0.0 0.0 0.0 <10 <10 <0.0032 <0.0032 NSD
Ist Floor W/I 10' Of Elevator + Bath
10 DC092822 1200 A 0.0032 0.0 0.0 0.0 <10 <10 <0.0032 <0.0032 NSD
1st Floor Main Lobby
11+" DC092823 1200
Ist Floor W/I 10° Of C/R Barrier Between Corridor And Airlock SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUAL
12#* DC092824 1200
Ist Floor Between Back Door + Airlock ‘SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUALITATIVE SCAN/
* concentration represented by the detection of I structure
** not analyzed 9/29/01
NSD. No Asbestos Structures Detected Reviewed By: | ; Analyzed By: Date:
Aleksandr Barengolts
NVLAP#: 200546-0)