NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 53/80 WEST STREET Block: 55 Lot: 16 BIN: 1001061 85 West Street, NY Financial Center Marriott, 16-26 Albany Street, 122-130 Washington Street
Document / 129 pages

Document fragment from DEP Box 53 regarding West Street

Machine-extracted title · confidence 60%

Fragmented record associated with the 80 West Street and Financial Center folder in DEP Box 53.

NYC-WTC_000131145–000131273

Folder label: “80 WEST STREET Block: 55 Lot: 16 BIN: 1001061 85 West Street, NY Financial Center Marriott, 16-26 Albany Street, 122-130 Washington Street

Page image
Scanned page image, NYC-WTC_000131197
OCR text

OCR status: ocr · source: ours

NYC-WTC_000131197 HBHREHEESEEH &SES& er ike STO aee BHRHHRHHEHEEHEHHEHHRHHHAREHBRHEEHEEHEE EE Client Name: Hillmann Environmental Company, Inc. Table I Summary of Transmission Electron Microscopy (TEM) Results for Asbestos (air) Marriot; 85 West Street (Roy's Resturant) Structure Structure Air Area x Analytical Asbestos Structures Detected Density Concentration Type SciLab Client Dilution Filtered Analyzed Sensitivity (Microns) (struc/sq. mm.) —_(struc/cc air) of Sample # Sample # Factor (liters) (sq.mm.) (struc/ccair) 0.5-5.0 >5.0 Total >5.0 Total >5.0 Total Asbestos oi** DC092801 1200 Ist Floor WAI 10' Of Elevator + Bath SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUALITATIVE SCAN/ 02** DC092802 1200 Ist Floor Main Lobby /SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUALITATIVE SCAN/ o3** DCO92803 1200 Ist Floor WA 10° Of C/R Barrier Between Corridor And Airlock /SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUAL 04** DC092804 1200 Ist Floor Between Back Door + Airlock /SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUALITATIVE SCAN/ 0s** DC092809 1200 Ist Floor W/I 10' Of Elevator + Bath SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUALITATIVE SCAN/ 06 DC092810 1200 A 0.0032 0.0 0.0 0.0 <10 <10 <0.0032 <0.0032 NSD Ist Floor Main Lobby 07 DC092812 1200 A 0.0032 0.0 0.0 0.0 <10 <10 <0.0032 <0.0032 NSD Ist Floor Between Back Door + Airlock 08 DC092820 1200 A 0.0032 0.0 0.0 0.0 <10 <10 <0.0032 <0.0032 NSD 1st Flooor Between Back Door + Airlock 09 DC092821 1200 | 0.0032 0.0 0.0 0.0 <10 <10 <0.0032 <0.0032 NSD Ist Floor W/I 10' Of Elevator + Bath 10 DC092822 1200 A 0.0032 0.0 0.0 0.0 <10 <10 <0.0032 <0.0032 NSD 1st Floor Main Lobby 11+" DC092823 1200 Ist Floor W/I 10° Of C/R Barrier Between Corridor And Airlock SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUAL 12#* DC092824 1200 Ist Floor Between Back Door + Airlock ‘SAMPLE OVERLOADED WITH >25% PARTICULATE. NO VISUAL ASBESTOS BY QUALITATIVE SCAN/ * concentration represented by the detection of I structure ** not analyzed 9/29/01 NSD. No Asbestos Structures Detected Reviewed By: | ; Analyzed By: Date: Aleksandr Barengolts NVLAP#: 200546-0) NYC 9/11 Public Portal Document

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000131197Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →