WTC environmental lab report and data distribution, January 2002

Machine-extracted title · confidence 65%

57-page lab report documenting World Trade Center environmental test results distributed to multiple federal, state, and local agencies including CDC and EPA.

NYC-WTC_000130550–000130606

Folder label: “E-Mail 1/2/02

Page image
Scanned page image, NYC-WTC_000130581
OCR text

OCR status: ocr · source: ours

NYC-WTC_000130581 NYC Response Asbestos Air Sampling Results for Staten !sland Landfill Sampling Date and Times: 12/21/01 0750 to 2204 Data Validation Date: 12/27/2001 PCM by NIOSH 7400 TEM ( AHERA) Sampling Sampling | Sample Structures (#) Date Sample No. Location | Volume*} Matrix fimm? ficc 0.5p - 5y Su Simm? | $~ficc™* 12/21/01 LFO1712 P-1 720 Air <7.0 <0.004 <8.75 | <0.0047 12/21/01 LFO1713 P-2 666 Air <7.0 <0.004 <7.87 | <0.0046 12/21/01 LFO1714 P-3 720 Air <7.0 <0.004 <8.75 | <0.0047 42/21/01 LFO1715 P-4 720 Air <7.0 <0.004 <8.75 | <0.0047 12/21/01 LFO1716 P-5 720 Air <7.0 <0.004 <8.75 | <0.0047 12/21/01 LFO1717 P-6 NS Air NS NS NS NS 12/21/01 LF01718 P-7 695 Air <7.0 <0.004 <8.75 | <0.0048 12/21/01 LFO1719 P-8 720 Air <7.0 <0.004 <8.75 | <0.0047 12/21/01 LFO1720 W-11 720 Air 8.92 0.005 <8.75 | <0.0047 12/21/01 LFO1721 W-12A 720 Air 10.19 0.005 <8.75 | <0.0047 12/24/01 LF01722 W-12B 720 Air <7.0 <0.004 <8.75 | <0.0047 12/21/01 LF01723 B-13 716 Air <7.0 <0.004 <8.75 | <0.0047 12/21/01 LFO1724 B-14 720 Air <7.0 <0.004 <8.75 | <0.0047 42/21/01 LFO1725 T-15 720 Air <7.0 <0.004 <8.75 | <0.0047 12/21/01 LF01726 T-16 720 Air <7.0 <0.004 <8.75 | <0.0047 12/21/01 LFO1727 0-17 NS Air NS NS NS NS 12/24/01 LF01728 0-18 700 Air <7.0 <0.004 <8.75 | <0.0047 12/21/01 LF01729 0-19 720 Air <7.0 <0.004 <8.75 | <0.0047 42/21/01 LFO1730 MPHS-20 720 Air <7.0 <0.004 <8.75 | <0.0047 12/21/01 LFO1731 Lot Blank 0 Air <7.0 n/a NA?) NA®) 12/21/01 LF01732 Trip Blank 0 Air <7.0 nia NA®) NA?) dlolololalYlojafolojojolojojolBicjolo} ojo ofololololYlolojojalolojolojo|Yjojalo| ojo Key: * Sample volume (liters) is below recommended limit for the TEM method; volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) Sad NA“. Not analyzed due to overloading of particulates NA @)- Not analyzed for TEM n/a - Not applicable NC - Sample not collected NS - Sample not submitted NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 Simm’, volume 1200 L, for 25 mm filter (TEM) FK-12-21-01-am NYC 9/11 Public Portal Document

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000130581Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000130435 · Box DEP Box 53

Summary of asbestos air sampling results from October 1, 2001, including PCM and TEM standard comparisons for NYC and NJ locations.

Filed in the same folder

NYC-WTC_000130438 · Box DEP Box 53

Draft special investigative audit report on environmental data from the World Trade Center site prepared by IT Corporation.

Filed in the same folder