NYC 9/11 Public Portal Document
Attn: Fred Burkhardt Received: 9.-16/02 8:00:00 Aft
ATC Associates Inc. ATC Group #: 8841
. 104 East 25th Street Analysis Date: 9/18/02
New York NY 10010
Fax: (212) 353-3599 Phone: (212) 353-S280
Project: DEP Cleaan-up Project #: 22906-0002
125 Cedar Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
.-1nal)Tical Asbestos
Area .Volt Asbestos # Structures Sensitivity Concentration
Sample Volume .4naly:ed Asb Types) 0.5p-5 5p ('S/cc) (S/mm') (S/cc) Notes
11 2400.00 0.0450 U None Detected 0 0 0.0036 <22.24 <0.0036
8841 -8
12 2400.00 0.0450 0 CHRYSOTILE I I 0.0036 44.48 0.0071
8841 -9
13 2410.00 0.0450 0 None Detected 0 0 0.0036 <22.24 <0.0036
884/ -iii
1-1 2410.00 0.0450 0 CHRYSOTILE 3 0 0.0036 66.73 0.0107
.4.5'4/ -/1
2420.01) 0.0450 0 None Detected 0 0 0.0035 <22.24 <0.0035
~4Y4/ _/2
16 2420.1)0 0.0451) 0 None Detectea 0 0 0.0035 , 22.24 ., 0.0035
s,4/ -/3
17 2430.00 0.0450 0 CHRYSOTILE I 0 0.0035 22.24 0.0035
6841 -14
18 2400.00 0.0450 0 None Detected 0 0 0.0036 <22.24 <0.0036
8841 -l5
19 2400.00 0.0450 0 None Detected 0 0 0.0036 <22.24 <0.0036
884/ -/6
ROMAN PEPS K V MICHAEL .A GORYCKI, Ph D.
lnatvied by pproved by
Disclaimer The laboratory is not responsible for data reported in structures/cc. which is dependent on volume colt a bby non-laboratory personnel. This is only responsible
for data reported in structures/mm'. This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
• product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLMITEM #101187-0. NY State ELAP #10879
Page ? o/
NYC-WTC 000129728
OCR can misread numbers and units. Confirm readings against the page image before using them.