NYC 9/11 Public Portal Document
ATC Associates _ y 3
104 East 25 Street, New York, NY 10010
Phone: (212) 353-8280 Fax: (212) 353-3306
Attn: Benjamin Sallemi Received: 9/27!02 8:00:00 AM
ATC Associates Inc. ATC Group #: 8900
104 East 25th Street Analysis Date: 9/27/02
New York NY 10010
Fax: (212)353-3599 Phone: (212)353-8280
Project: DEP Clean-up Project #: 22906-0002
125 Cedar Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TENT) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
.4nalytical .4sbestos
.Area Nun .-tshestes # Structures Sensitivity Concentration
Sample Volume Analyzed Asti Type() O.Sp-S Sr (S/cc (Simm'j (S/cc) Notes
03 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.004S
8900 -/
04 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048 ~•-
8900 -'
._.-
5 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
900 -3
06 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8900 -4
07 1800.00 0.0450 0 None Detected, 0 0 0.0048 <22.24 <0.0048
8900 -5
MARK PEYSAKHOV MICHAEL A. GORYCKI. Ph.D.
Analyzed b Approved by:
Cisdaimer The laooratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is n y responsible
for aam reposed in structureslmm'. This report may not be reproduced, except in full, without written approval oy ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only !o the samples repgrted above. Quality control data rinc:uding 95%
confidence limits and laboratory ano analysis' accuracy and precision) is available upon request
:ccreai[ea for NVLAP P! MITEM #101187.0. NY State ELAP 410879
Page IoJI
NYC-WTC 000129913
OCR can misread numbers and units. Confirm readings against the page image before using them.